CALITEK Grizzly 600 Скачать руководство пользователя страница 9

ENGLISH

Thank you for purchasing Calitek LED multi-bar lights.

This manual describes the installation and use of your Calitek lighting equipment. Please read this manual 

carefully before installing or starting your LED system. If you are not familiar with installing high-performance 

lighting systems, it is recommended that you use qualified professionals.

HORTICULTURAL LIGHTING SYSTEM. NOT SUITABLE FOR THE ILLUMINATION OF HOUSEHOLD ROOMS.

LED LAMP FOR HORTICULTURAL LIGHTING

PRODUCT DESCRIPTION

Grizzly and Grizzly Pro are electronic horticultural LED lamps with a linear design consisting of six LED light 
bars. Grizzly and Grizzly Pro are high performance lightweight products recommended for commercial horticulture.

AMBIENT

Your Calitek lamp must be used in a climate-controlled growing location, in indoor farms or greenhouses. The 
product can be used in humid locations but should not be used in wet areas or outdoors. This product will work 

best between 20°C and 30°C. Do not exceed ambient temperatures above 35°C.
The product can be used in humid environments from 20% to 90%, without condensation

LEGAL INFORMATION

This product is CE certified in accordance with LVD, EMC and ROHS testing standards.

SAFETY RECOMMENDATIONS AND WARNINGS

Always  refer  to  local  rules  and  regulations  before  installing  or  using  this  Calitek  lamp.  -  Do  not  open  or 

disassemble the LED lamp as it contains non-replaceable parts inside. Opening or tampering with 

theCalitek  lamp  may  be  dangerous  and  will  void  the  warranty.  Do  not  use  this  Calitek  lamp  if  the 

Grizzly lamp or the power cable is damaged. If the power cable is damaged, it must be replaced exclu-

sively  by  the  manufacturer.  Modifications  to  the  cables  may  cause  undesired  electromagnetic  effects, 

which may render the operation of the product unsuitable for legal requirements. Do not expose this 

Calitek  lamp  to:  Condensed  moisture,  thick  fog  or  direct  spray;  ambient  temperatures  exceeding  those 
specified;  dust  and  pollution;  sunlight  or  HID  light  which  may  lead  to  overheating  of  the  transformer.

 

Содержание Grizzly 600

Страница 1: ...FR EN...

Страница 2: ...ION DISTRIBUTION DE LUMI RE 120 MOUNTING HEIGHT HAUTEUR DE MONTAGE 50 CM Above Canopy THERMAL MANAGEMENT GESTION DE LA CHALEUR Passive MAX AMBIENT TEMPERATURE TEMP RATURE MAX AMBIANTE 95 F 35 C CONTRO...

Страница 3: ...ables l int rieur L ouverture ou la modification de la lampe LED peut tre dangereux et r voquera la garantie Utilisez pas la lampe Calitek si celle ci ou le c ble d alimentation sont endommag s Si le...

Страница 4: ...pour nettoyer la lampe car cela pourrait endommager les optiques secondaires Utilisez un chiffon tissu propre et sec la place N utilisez pas la lampe proche de substances inflammables explosives ou r...

Страница 5: ...GE DU CADRE 1 Connectez les supports A et B au ch ssis principal en appuyant sur le bouton du connecteur de ch ssis et en les ins rant dans l embout et le verrou du ch ssis Attention Le transformateur...

Страница 6: ...des barres lumineuses dans la lampe comme montr ci dessus 4 INSTALLATION DE LA LAMPE Assurez vous que toutes les barres lumineuses soient install es de fa on s curis e Retournez la lampe et attachez l...

Страница 7: ...out de la lampe 1 au port RJ14 in de la lampe 2 c Continuez ainsi connecter les lampes en serie jusqu 100 lampes par contr leur 7 CONNEXION DE LA LAMPE LED L ALIMENTATION Assurez vous que l alimentati...

Страница 8: ...ent que les c bles de la lampe ne soient pas endommag s STOCKAGE RECYCLAGE Placez la lampe Grizzly dans un environnement sec et propre ayant une temp rature ambiante situ e entre 25 C et 55 C Le produ...

Страница 9: ...tdoors This product will work best between 20 C and 30 C Do not exceed ambient temperatures above 35 C The product can be used in humid environments from 20 to 90 without condensation LEGAL INFORMATIO...

Страница 10: ...ning agents to clean the LED lamp as this could damage the secondary optics Use a clean dry cloth cloth instead Do not use the LED lamp near flammable explosive or reactive substances This LED lamp ca...

Страница 11: ...he CALTEK light under load MOUNTING INSTRUCTIONS 1 FRAME ASSEMBLY 1 Connect brackets A and B to the main chassis by pressing the button on the chas sis connector and inserting them into the end cap an...

Страница 12: ...magnetic connection is secure Assemble the rest of the light bars into the fixture frame as shown in the figure above 4 INSTALLING THE FIXTURE Ensure all light bars are installed correctly and are sec...

Страница 13: ...e fixture 1 RJ14 port in b Connect RJ14 out of fixture 1 to RJ14 in of fixture 2 c Continue to connect fixtures in series for up to 100 fixtures per controller 7 CONNECTING THE LED FIXTURE TO THE MAIN...

Страница 14: ...ture using a dry or damp cloth Regularly check the cables of the LED fixture to ensure it is undamaged STORAGE AND DISPOSAL Store the Grizzly fixture in a dry and clean environment with an ambient tem...

Страница 15: ...IS 32 34 rue de la R gale F 77181 COURTRY CONTENTS 1x MANUAL 2x METAL CABLE HANGERS 1x FRAME A 1x LED DRIVER Power output cables male connectors to face Frame B 1x FRAME B Contains power input cables...

Страница 16: ......

Отзывы: