Always fit the fuses close to the positive terminals of
the batteries and the D+ of the dynamo!
16
17
18
19
20
21
22
23
24
25
26
27
6 mm²
red
6 mm²
minus
blue
10 mm²
+ supply
red
0,75 mm²
D+ generator
brown
0,75 mm²
B+ measuting cable
test
red
2 A
**
40 A
**
6 mm²
red
2 A
**
40 A
**
30 A / 40 A
✪
*
I
12 V battery
(start)
II
12 V battery
(supply)
+ charging current
✪
Fuse 30 A on EVS 36/20-DS/IU
Fuse 40 A on EVS 36/30-DS/IU
* Fuse is required for cable lengths over 1 m!
** Fuse absolutely required!
The fuses serve exclusively to protect the circuits.
For lines longer than 3 m, see table on page 30.
Fig. 14: Connection diagram 12-pole plug connector
Connecting to the control panel
Plug the 7-pole ribbon cable into your control
panel. The assignation of the contacts is accord-
ing to the following list.
7 6 5 4 3 2 1
Fig. 15: 7-pole connector
Contact 1
Negative connection
Contact 2
Positive test connection for battery II
Contact 3
Positive test connection for battery I
Contact 4
Control connection for consumer relay
Contact 5
Output for charge control
Contact 6
Output for Tremat signal
Contact 7
Control connection for pump relay
Plug the 7-pin ribbon cable into the associated port on the de-
vice (fig. 4, pos. 8). The ribbon cable can only be inserted into
the correct socket on the device when in the correct position.
Do not use any force.
Temperature sensor
If you are using a temperature sensor for the
battery II, stick the temperature sensor to the
face of the battery II (supply battery). To do so,
remove the protective plastic film from the
sticking spot of the temperature sensor and
press it firmly to the desired position at bat-
tery II (see description of temperature sensor).
Connect the cable of the temperature sensor to
the temperature sensor connection of the
device (2-pole connection – fig 4, pos. 6).
Fig. 16: Temperature sensor