1. As a standard practice, drain water from the air compressor tank and air lines prior to use each
day (reference your compressor operators manual for detailed instructions).
2. Install a 1/4” male connector (not included) into the air inlet port on the tool.
3. Turn on the air compressor and allow it to build up pressure.
4. To assemble the backing disks and sandpaper.
5
. Adjust the air compressor’s regulator or the supply line regulator to 90PSI.
6. Connect the tool to the air hose quick coupler.
7. Adjust the regulator control knob to the desired variable speed.
8. Squeeze trigger gently. Start the sander off the work. Set it down on the outer portion of the sandpaper
with tool held at a slight angle to the work surface. Move the sander slowly back and forth in wide
overlapping areas. Let the sander do the work surface. Do not put additional pressure on the sander.
This slows down the speed of the pad, reducing sanding efficiency and puts additional burden on the
air tool motor.
9. When finishing sanding, lift sander off the work before releasing the trigger.
Maintenance
WARNING:
Disconnect tools from air supply before changing accessories, servicing or performing maintenance.
Replace or repair damaged parts.
Use genuine parts only. Non-authorized parts may be dangerous and
will invalidate the warranty.
1. Lubricate the air sander daily with a few drops of air tool oil dripped into the air inlet
2. Clean the tool after use. DO NOT use worn or damaged tool.
3. Loss of power or erratic action may be due to the following:
a)
Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose
connectors. To remedy check the air supply.
b
) Grit or gum deposits in the tool may also reduce performance. If your model has an air strainer
(located in the area of the air inlet), remove the strainer and clean it.
4. When not in use, disconnect from air supply, clean tool and store in a safe, dry, childproof location.
Trouble Shooting
The following form lists the common operating system with problem and solutions. Please read the form
carefully and follow it.
WAR N IN G:
If any of the following symptoms appears during your operating, stop using the tool immediately, or
serious personal injury could result. Only a qualified persons or an authorized service center can perform
repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing O-rings or
Cylinder, lubricate with air tool oil before assembly.