background image

TO GAIN ACCESS TO PROPANE CYLINDER:

1. Locate access door on appliance.

2. Use handle to pull door open, disconnecting magnetic latch.

BURNER MEDIA INSTALLATION

A. Carefully inspect the burner and log cartons for shipping damage. If any parts are missing or

damaged, call your dealer.

Do not attempt

to install the appliance unless all parts are in good

condition.

B. Correct installation is crucial to safe performance of your Outdoor Fire Pit.
C. Due to high temperatures, the Fire must be located out of traffic areas and away from combustibles.

LAVA GRANULES & LOG PARTS LIST

Replacement parts available from your local retailer.

Содержание OUTDOOR LIVING REDEFINED OUTDOOR FIREPIT

Страница 1: ...appliance is for connection to a fixed piping system the installation must conform with local codes or in the absence of local codes the National fuel Gas Code ANSI Z223 1 NFPA 54 or International Fuel Gas Code Installer Leave This Manual with Consumer Consumer Save this Manual for Future Reference WARNING improper installation adjustment alteration service or maintenance can cause injury or prope...

Страница 2: ...ETY INFORMATION READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIREPIT If not installed and used correctly per these instructions this product can cause serious injury CAUTION INSTALLATION MODIFICATION AND REPAIR MUST BE DONE BY A QUALIFIED PROFESSIONAL INSTALLER Be sure you understand all safety precautions and warnings contained in this manual 1 CHECK STATE AND LOCAL CODES TO DETER...

Страница 3: ...nt is 5 inches water column and maximum inlet gas supply pressure is 10 inches water column FOR PROPANE The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches water column and the maximum inlet gas supply pressure is 13 inches water column 6 Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur i...

Страница 4: ...f Dangerous Goods and Commission CAN CSA B399 BEFORE INSTALLATION BE SURE THE PROPANE TANK IS TURNED OFF To connect to the propane gas tank attach the black hose with regulator and tighten down the connector see photos below Follow all instructions and safety warnings supplied with the propane tank Propane cylinder must have a listed over filling protection device Turn on the gas to the burner sys...

Страница 5: ...shipping damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good condition B Correct installation is crucial to safe performance of your Outdoor Fire Pit C Due to high temperatures the Fire must be located out of traffic areas and away from combustibles LAVA GRANULES LOG PARTS LIST Replacement parts available from your local ...

Страница 6: ...anules into the Outdoor Firepit so that it completely covers the burner See figures 1 and 2 2 Place the largest log diagonally centered over the burner See figure 3 3 Place the other logs as desired using the first log figure 3 as a support to lean the other logs against See figure 4 ...

Страница 7: ...SOME TIME AFTER USE YOU MUST MAINTAIN THE LOG LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR LOG SET IF YOU NEED TO REPOSITION ANY LOG TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW LOGS ADEQUATE TIME TO COOL BEFORE HANDLING FIGURE 3 FIGURE 4 ...

Страница 8: ...bag s of ARCTIC FLAME GLASS into the Outdoor Firepit so that it completely covers the burner See figures 1a and 2b 2 Place all of the enclosed ARCTIC FLAME GLASS into the burner Not using all of the glass may result in a low flame Figure 1a Figure 2b ...

Страница 9: ...hnician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Firepit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMATION ABOVE 1 Turn the manual gas control slig...

Страница 10: ...T hang clothing or any flammable material on or near your Firepit Matches paper garbage or any other material must not be thrown on top of the logs burner or into the flame I DO NOT use your Firepit if any part of it has been under water Immediately call a qualified service technician to inspect the set and to replace any part of the control system and any gas control which has been under water J ...

Страница 11: ...nd the point of contact between the cylinder and the retention means 2 The LP gas supply cylinder to be used must be constructed and marked in accordance with the U S Department of Transportation D O T Specifications for LP Gas Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable 3 The LP cylinder must be provided with a listed overfilling pre...

Страница 12: ...your fire ring or enclosure 4 Carefully detach the connector hose attached to the orifice holder and unscrew the orifice holder from the burner pipe 5 Remove the orifice from the holder and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 6 If you are converting from natural gas NG to propane LP gas slide the air shutter so that the air intake hole...

Страница 13: ...Outdoor Concepts Parts List Burner Pan Part 804 Orifice with Air Mixer Part 803 Connector Hose Part 812 Valve Part 805 Nipple Part 809 Brass Jam Nut Part 811 Gas Knob Part 807 Hose and Regulator Assembly Part 812 ...

Страница 14: ...Replacement Parts are Available from Your Dealer ...

Страница 15: ...sland 7310 Palm Chat 7140 Monterey Coffee Table 7320 Palm Dining 7330 Palm Bar 7410 Tradewinds Chat 7420 Tradewinds Dining 7430 Tradewinds Bar 7520 La Jolla 7550 La Paz 7610 El Paseo 7611 Rodeo Chat 7651 Rodeo Balcony 17671 Irvine Blvd Suite 108 Tustin CA 92780 Toll Free 877 274 6773 Fax 877 274 0017 www californiaoutdoorconcepts com Use your smart phone QR code reader to view Follow us on Faceboo...

Страница 16: ...egulator the appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at pressures in excess of psi 3 5 kPa The appliance must be isolated from gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas line at test pressures equal to or less than psi 3 5 kPa LP Gas...

Отзывы: