User Manual - Rev AJ
California Instruments
9.4.6.1 DIPS AND INTERRUPTIONS TEST
Scroll to the DIPS AND INTERRUPTIONS entry using the up and down cursor keys. Press the
ENTER key to select the DIPS AND INTERRUPTIONS menu. The screen will appear as shown
in Figure
Figure 9-15: IEC Dips and Interrupts
This field enables or disables the -411 test mode.
ATE
This field is not available on MX Series systems.
L
The RUN ALL selection will cause the following automated test sequence sugg
STATE
EOS ST
RUN AL
ested by the
standard to be run:
Step
Output in
% of U
T
No of Cycles
Start angle
(Degrees)
Repeat #
times
Delay
between
repeats (s)
1 0 0.5
0
3
10
2 0 0.5
180
3
10
3
0
1
0,45,90
3 at diff ø
10
4
0
5
45,90,135
3 at diff ø
10
5
0
10
90,135,180
3 at diff ø
10
6
0
25
180,225,270
3 at diff ø
10
7
0
50
270,315,0
3 at diff ø
10
8 40 0.5
0
3
10
9 40 0.5
180
3
10
10
40
1
0,45,90
3 at diff ø
10
11
40
5
45,90,135
3 at diff ø
10
12
40
10
90,135,180
3 at diff ø
10
13
40
25
180,225,270
3 at diff ø
10
14
40
50
270,315,0
3 at diff ø
10
15 70
3
10
0.5
0
16 70
0.5
180
3
10
17
70
1
0,45,90
3 at diff ø
10
18
70
5
45,90,135
3 at diff ø
10
19
70
10
90,135,180
3 at diff ø
10
20
70
25
180,225,270
3 at diff ø
10
21
70
50
270,315,0
3 at diff ø
10
Table 9-19: Dips and Interruptions Tests Performed During RUN ALL
The user can change the NOMINAL Ut voltage for this. The RUN ALL Command line will change
to ABORT during the test. Selecting ABORT and pressing the ENTER key will terminate the test
at any time and the output voltage will return to the nominal value.
PHASE SELECTION
MX
Series
208
Содержание MX30-1
Страница 4: ...User Manual Rev AJ California Instruments 4 MX Series ...
Страница 33: ...User Manual Rev AJ California Instruments MX Series 33 ilter option schematic Figure 2 12 MX output f ...
Страница 34: ...User Manual Rev AJ California Instruments Figure 2 13 MX45 Output Noise 10 KHz 1 MHz 34 MX Series ...
Страница 50: ...User Manual Rev AJ California Instruments Figure 3 11 MX135 or MX135 MB Output Wiring Rear view 50 MX Series ...
Страница 147: ...User Manual Rev AJ California Instruments Output Status Available on top assembly 7003 427 only MX Series 147 ...
Страница 148: ...User Manual Rev AJ 148 California Instruments MX Series Figure 5 2 MX Series Detailed Block Diagram ...
Страница 149: ...User Manual Rev AJ MX Series California Instruments 149 Figure 5 3 Power Module Detailed Block Diagram ...
Страница 195: ...User Manual Rev AJ California Instruments Figure 9 4 Voltage Modulation MX Series 195 ...