ALIGN & TRIM VALVE STEM 

 

Remove MUDGUARD (

1a

) from VALVE (

1

)

 

 

 

To  obtain  proper  HANDLE  (

11

)  alignment  it  may 

be  necessary  to  re-align  cartridge  STEM  (

1b

);  to 

align STEM (

1b

), slightly loosen the cartridge NUT 

(

1d

),  place  HANDLE  (

11

)  on  STEM  (

1b

)  and 

TIGHTEN

  in  CW  direction  until  desired 

alignment is achieved; retighten cartridge NUT (

1d

to factory torque setting of 14 ft-lbs. 

 

WARNING:   

Cartridge  NUT  (

1d

MUST

  be  properly  torqued  to 

prevent possible failure and/or water damage

 

 

 

Using  a  marking  device  (e.g.  pencil  or  marker) 

indicate  a  distance  of  13/16

”  from  finished  wall  on 

ALL-THREAD  (

1c

);  unscrew  ALL-THREAD  (

1c

from valve STEM (

1b

)

 

 

 

Cut STEM (

1b

)

 

1-3/4

” from finished wall surface

 

 

 

Cut off excess ALL-THREAD (

1c

) at indicated mark 

and  reattach  ALL-THREAD  (

1c

)

 

onto  valve  STEM 

(

1b

)

 

 repeat on other side

 

 

 
 
 

 

INSTALLING ESCUTCHEON

 

 

 

Tighten handle RING (

8

) and decorative NUT (

10

onto handle RISER (

9

)

 

 

Secure  escutcheon  onto  wall  by  tightening 
decorative NUT (

10

) onto ALL-THREAD (

1c

 

 

 

 

 

 

 

INSTALLING HANDLE

 

 

Loosen both SETSCREW (

11b

 

Slide  HANDLE  (

11

)  down  onto  and  engage  valve 

STEM (

1b

) leaving a space of 1/32” between handle 

and decorative NUT (

10

 

Tighten both SETSCREW (

11b

)

 

 

 

Turn on water supply and check for leaks 

 
 

 
 
 

 
 

californiafaucets.com    

5271 Argosy Ave. Huntington Beach, CA 92649    800-822-8855

 

1c 

10 

11 

11 

1b 

11b 

11 

1d 

1c 

13/16”

 

hex 

1b 

1b 

1-3/4

 

1c 

13/16

 

10 

Отзывы: