ALIGN & TRIM VALVE STEM
•
Remove MUDGUARD (
1a
) from VALVE (
1
)
•
To obtain proper HANDLE (
11
) alignment it may
be necessary to re-align cartridge STEM (
1b
); to
align STEM (
1b
), slightly loosen the cartridge NUT
(
1d
), place HANDLE (
11
) on STEM (
1b
) and
TIGHTEN
in CW direction until desired
alignment is achieved; retighten cartridge NUT (
1d
)
to factory torque setting of 14 ft-lbs.
WARNING:
Cartridge NUT (
1d
)
MUST
be properly torqued to
prevent possible failure and/or water damage
•
Using a marking device (e.g. pencil or marker)
indicate a distance of 13/16
” from finished wall on
ALL-THREAD (
1c
); unscrew ALL-THREAD (
1c
)
from valve STEM (
1b
)
•
Cut STEM (
1b
)
1-3/4
” from finished wall surface
•
Cut off excess ALL-THREAD (
1c
) at indicated mark
and reattach ALL-THREAD (
1c
)
onto valve STEM
(
1b
)
–
repeat on other side
INSTALLING ESCUTCHEON
•
Tighten handle RING (
8
) and decorative NUT (
10
)
onto handle RISER (
9
)
•
Secure escutcheon onto wall by tightening
decorative NUT (
10
) onto ALL-THREAD (
1c
)
INSTALLING HANDLE
•
Loosen both SETSCREW (
11b
)
•
Slide HANDLE (
11
) down onto and engage valve
STEM (
1b
) leaving a space of 1/32” between handle
and decorative NUT (
10
)
•
Tighten both SETSCREW (
11b
)
•
Turn on water supply and check for leaks
californiafaucets.com
5271 Argosy Ave. Huntington Beach, CA 92649 800-822-8855
1c
10
9
8
11
11
1b
11b
11
1d
1c
13/16”
hex
1b
1b
1-3/4
”
1c
13/16
”