CF-TO-V3002-X_ii_190131
Pg 1
Descanso
®
CF-TO-V3002-7, CF-TO-V3002-9
CF-TO-V3002X-7 & CF-TO-V3002X-9
In-Wall Vessel Lavatory Faucet
Installation Instructions
1
IMPORTANT: Read all instructions prior to installation and provide copy of instructions to consumer.
Operating Specifications:
Recommended Supply Pressure:
20 to 70 psi
*†
Maximum Flow Rate:
1.2 gpm
*
Operating pressures between hot and cold supplies should vary no more than 30 psi.
†
If water pressure exceeds 70 psi, install a Pressure-Reducing Valve (PRV).
INSTALLING SPOUT TO IN-WALL VALVE
•
Prior to installing faucet trim in-wall vessel rough
VALVE (
1
),
CF-VL-R
, must be properly installed
and wall surface must be completely finished
NOTE:
Recommended through-hole size shall be
Ø
1-1/4
”
•
Apply thread sealant to both threaded ends of NPT
NIPPLE (
2
), not supplied, and tighten into center
outlet of VALVE (
1
)
•
Tighten spout BASE (
4
) onto spout RING (
5
), and
slide onto SPOUT (
3
)
•
Tighten SPOUT (
3
) onto NPT NIPPLE (
2
)
•
If SPOUT (
3
) is not properly aligned when fully
tightened, turn counter-clockwise till properly
aligned
IMPORTANT:
Do not overtighten SPOUT (
3
)
•
Push spout RING (
5
) firmly against wall, positioning
setscrew hole on bottom, and tighten SETSCREW
(
6
)