California Air Tools 8010SPC Скачать руководство пользователя страница 9

9

Customer Support: 1-866-409-4581

AIR COMPRESSOR

test run

before using the air compressor for the first time, complete a test

run as follows:

1.

Turn the power switch to the OFF position. Plug the power

supply cord into a power supply socket. Start the air

compressor by turning the power switch to the ON position.

The pressure gauge reading will slowly rise as pressure

increases inside the air tank. When the gauge reading reaches

115 PSI, the pressure switch will automatically turn the power

off. This indicates the compressor is working normally. 

2.

daily operation

Starting the compressor:

1.

Turn the power switch to the OFF position.

2.

Attach the air hose to the 1/4” air hose connection.

3.

Close the drain valve. 

4.

Plug the power supply cord into a power supply socket.

5.

Turn the power switch to the ON position.

6.  

Let the motor run and tank fill until motor turns off.

7.

Operate air tool normally. 

8. 

To regulate the air to the air hose, have the air compressor and 

air tool both turned on and running. Turn the Regulator knob 
to the right to increase pressure and turn left to decrease the
pressure to the hose and air tool.

9.

Only operate continously for 1 hour maximum.

Allow compressor to cool down before restarting.

Shutting down the compressor:

1.

Turn the power switch to the OFF position.

2.

unplug the power supply cord.

3.

Reduce the pressure in the air tank through the air supply

hose.

Air compressor surfaces become hot during 
operation.

DO NOT touch hot surfaces, because they can cause 
severe burns.

Do not touch the air compressor’s cylinder head. 
During operation, the cooling fins of the cylinder 
head and delivery pipe become hot.

Allow the air compressor to cool before touching it.

DO NOT place a storage cover on the unit during 
operation. Only place a cover on the air compressor 
after it has thoroughly cooled down.

FIRE

HOT SURFACE

WARNING

Flying objects can cause injury to the eyes, head and 
other parts of the body.

Air-powered equipment and power tools are capable 
of propelling items (metal chips, fasteners and 
particulates) at high speed into the air and could 
result in injury.

Always wear approved head and eye protection.

Never point the air stream at any part of your body, 
or at another person or animal.

When operating the air compressor, make sure all 
other people and animals maintain a safe distance.

Do not move the air compressor when the air tank is 
under pressure. 

Never use the air hoses to pull or move the air 
compressor.

Keep the air compressor on a flat surface.

WARNING

FLYING OBJECTS

note: 

If the Air Compressor is not working properly, the

pressure gauge will indicate that there is a decrease in

pressure in the air tank. If there is an air leak from the

compressor the pressure in the air tank decreases, the

pressure switch resets and the motor automatically turns

back on.
If you detect an air leakage, turn the power switch to the

Off position, release the air from the tank by pulling on

the safety valve. unplug the power supply cord and contact

Customer Support for Assistance.

Turn the power switch to the Off position, unplug the power

supply cord and release the air from the drain valve.

At this point proceed to the next step (daily operations)

starting the air compressor to continue to use.

Содержание 8010SPC

Страница 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 8010SPC WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Страница 2: ...enance _________________________________10 draining the air tank ___________________________10 changing the air filter__________________________10 testing for leaks ______________________________10 cleaning _____________________________________10 Storage______________________________________10 trouBleShootIng ____________________________11 SpecIfIcatIonS________________________________12 electrica...

Страница 3: ...r compressor do not return your air compressor for service or parts to the store dealer where purchased IMPORTANT SAFeTy INSTRuCTIONS Safety messages Signal Words DANGER Moving parts can cause severe trauma Keep hands and feet away from rotating parts tie up long hair remove jewelry and DO NOT wear loose clothing KICKBACK DANGER There is a danger of electric shock Use only undamaged electrical cor...

Страница 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Страница 5: ...f extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills a...

Страница 6: ...6 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Страница 7: ...r compressor should not be used in areas where dust or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solven...

Страница 8: ...pressed air discharges in the air tank A pressure gauge displays the pressure inside the tank When the pressure inside the tank rises to 115 PSI the power is automatically cut off by the pressure control switch When the pressure inside the tank lowers to 85 90 PSI the power is turned back on by the pressure control switch This gradually raises the pressure in the air tank This procedure happens re...

Страница 9: ...ouch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts...

Страница 10: ...ormance Therefore the air filter must be replaced regularly 1 Open the lid on the air filter then remove the old filter 2 Replace it with a new filter then close the lid testing for leaks Make sure all connections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the a...

Страница 11: ...es not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down Press the reset button to restart ensure that ...

Страница 12: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Страница 13: ...ecific legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties t...

Страница 14: ...itions or in applications not recommended by California Air Tools Inc 7 Normal wear 8 The use of accessories or attachments not recommended by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the en...

Страница 15: ...ation date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _________...

Отзывы: