AIR COMPRESSOR

MAINTENANCE 

Draining the Air Tank 

The frequency at which you should drain the air tank depends on 
the environmental conditions and the amount of operating time 
logged. The average draining frequency is every 1 to 2 days. 

1.

 Place the air compressor above a container capable of holding 

water.  

2.

 With compressed air in the air tank, slowly turn the drain valve 

knob to the forward (open) or straight position.                    
The water in the air tank will drain out.  

3.

 After all of the accumulated water has drained out, turn the 

drain valve knob to the closed or left position in order to avoid 
leakage. 

4. 

Draining the air tank protects parts from rust and corrosion. 

 

Cleaning or Changing the Air Filter 

The air filter is designed to reduce noise and  help prevent 
particulates in the air from entering and damaging the air 
compressor. 

After being used for a period of time, the air filter will become 
clogged. This will reduce the air intake capabilities of the air 
compressor, reducing performance. Therefore, the air filter must 
be cleaned or replaced regularly. 

1.

 Open the lid on the air filter, then remove the air filter element. 

2.

 To clean the element blow off or brush off the dirt and dust. 

3.

  If clogged, replace with a new air filter. 

 

 

 

 

 

 

Testing for Leaks 

Make sure all connections are tight. Do not overtighten. 

A small leak in any hose or pipe connection will reduce the air 
compressor's performance. 

To test for small leaks, spray a small amount of soapy water on 
the area suspected of leaking. If the soap bubbles, replace the 
broken part. 

 

Cleaning 

Clean items with a soft brush, or wipe with a moistened cloth 
using a biodegradable solvent. 

Do not use flammable liquids such as gasoline or alcohol. Always 
keep parts clean from dirt and dust for better performance.

 

Pressure Switch 

The pressure switch is factory pre-set to shut off at between 

120 - 125  PSI and to re-start at between 90-95 PSI 

 

 

 

STORAGE 

Before storing for a prolonged period of time: 

 

1.

 Turn off the power supply. 

2.

 Disconnect the power cord from the power supply and wrap 

the power cord around the air compressor handle to reduce 
the risk of damage. 

3.

 Release all the pressure and water from the air tank by 

opening the drain valve. 

4.

 Clean the air compressor to remove all dirt and dust. 

5.

 Cover the air compressor with a cover to protect the unit from 

dust and moisture. 

6.

 Do not stack or store any items on top of or around the air 

compressor. Damage could occur.

Содержание 20020CR-22060

Страница 1: ...TRA QUIET OIL FREE AIR COMPRESSOR OWNER S MANUAL CALIFORNIA AIR TOOLS 20020CR 22060 2 0 HP 6 50 CFM 40 PSI 5 00 CFM 90 PSI 20 0 GALLON STEEL TANK WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Страница 2: ..._________________12 Draining the Air Tank ___________________________12 Changing the Air Filter__________________________12 Testing for Leaks ______________________________12 Pressure Switch _______________________________12 Cleaning _____________________________________12 STORAGE______________________________________12 TROUBLESHOOTING ____________________________13 SPECIFICATIONS_________________...

Страница 3: ...are wet Ensure that all cords are free of damage before connecting to the power supply Ensure that you have a sufficient electrical supply for supporting the requirements of the motor Improper installation of the grounding plug is able to result in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat terminal The wire ...

Страница 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Страница 5: ... heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills and other ...

Страница 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PRODUCT LABEL A B C D E F G H ...

Страница 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Страница 8: ...the air compressor Screw the air filters into the motor head ports Install the Wheel Kit 1 Slide Bolt 51 through Wheel 50 2 Slide the washer 49 onto Bolt 51 3 Slide the bolt 51 through the wheel support hole located on the front bottom of the air compressor tank 4 Attached the Washer 49 and Nut 48 to the Bolt 51and tighten firmly 5 Repeat steps 1 4 to assemble the other wheel 6 Slide Bolt 84 throu...

Страница 9: ...s clean The air compressor should not be used in areas where dust or particulates are in the air This will damage the motor and impair proper operation IMPORTANT Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gaso...

Страница 10: ...drain valve is off and that the pressure switch is in the OFF position 3 Ensure that the power supply you are going to use is operating normally 4 Insert the power supply cord into a dedicated 220 volt 15 amp power supply socket DANGER There is a danger of electric shock Use only undamaged electrical cords DO NOT touch bare wires or receptacles DO NOT operate air compressor in wet weather or in we...

Страница 11: ...s because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can...

Страница 12: ...en remove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter Testing for Leaks Make sure all connections are tight Do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking If the...

Страница 13: ...indings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop Use heavy duty extension cord...

Страница 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Страница 15: ... legal rights and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that ma...

Страница 16: ...Tools Inc 9 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc Registration Warranty registration with California Air Tools Inc is required on all products You can mail the enclosed registration form or register on line Trouble Shooting and Maintenance Guide California Air Tools provides a Troubling and Maintenance Guide on our web...

Отзывы: