background image

5

Customer Support: 1-866-409-4581

AIR COMPRESSOR

Improper care could lead to the air tank bursting or 
exploding.

Drain air tank daily or after each use to prevent 
moisture buildup in the air tank.

Rust can weaken the air tank and cause leaks or 
bursting. If rust is detected, replace tank 
immediately. Do not try to repair the air tank by 
welding, drilling or modifying it in any other way. 
These modifications can weaken the air tank and 
cause a hazardous condition.

If air tank develops a leak, replace the air tank 
immediately. Never repair, weld or make 
modifications to the air tank or its attachments.

Never make adjustments to the factory-set 
pressures.

Never exceed manufacturer's maximum-allowable 
pressure rating attachments.

Because of extreme heat, do not use plastic pipe or 
lead tin solder joints for a discharge line.

WARNING

EXPLOSION

Use caution to minimize risk of fire or explosion.

It is normal for the air compressor motor and 
pressure switch to produce sparks while operating. If 
sparks come in contact with vapors from gasoline or 
solvents, they may ignite and cause a fire or 
explosion.

Abrasive tools such as grinders, drills and other 
tools are capable of making sparks that can ignite 
flammable materials.

Always operate the air compressor a safe distance 
away from flammable items. Use in well-ventilated 
areas.

Never exceed the maximum rated pressure.

FIRE

WARNING

EXPLOSION

Use caution when using extension cords.

Use an extension cord which is no more than 
25 feet long and at least 14 gauge.

Using an excessively long or thin-wired extension 
cord will cause severe damage to the motor.

Use only a 3-wire extension cord that has a 3-blade 
grounding plug.

CAUTION

Содержание 1020D

Страница 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 3010 4610 6310 4610A 1610A 4620A 1675A 1650A ...

Страница 2: ...ntenAnce _________________________________18 draining the Air tank ___________________________18 changing the Air filter__________________________18 testing for Leaks ______________________________18 Adjusting the pressure Switch ___________________18 cleaning _____________________________________18 StorAge______________________________________18 troubLeShootIng ____________________________19 Spec...

Страница 3: ... air compressor do not return your air compressor for service or parts to the store dealer where purchased IMPORTANT SAFeTy INSTRuCTIONS Safety messages Signal Words DANGER Moving parts can cause severe trauma Keep hands and feet away from rotating parts tie up long hair remove jewelry and DO NOT wear loose clothing KICKBACK DANGER There is a danger of electric shock Use only undamaged electrical ...

Страница 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Страница 5: ...f extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills a...

Страница 6: ... or becomes damaged turn off the power and drain the tank 4 Motors cannot be more than 10 lower or higher than the standard voltage 5 When the compressor is running do not touch its hot surfaces Routine maintenance 1 Always listen for unusual sounds vibrations or high pitched noises 2 Open the drain valves to empty the air tank at least once per day Weekly maintenance 1 Clean the air filter weekly...

Страница 7: ...ts hot surfaces Routine maintenance 1 Always listen for unusual sounds vibrations or high pitched noises 2 Open the drain valves to empty the air tank at least once per day Weekly maintenance 1 Clean the air filter weekly Replace it with a new one after 500 hours of use 2 Open the safety valve to ensure that it is operational 3 Ensure that the pressure switch and check valve are operating normally...

Страница 8: ...sten for unusual sounds vibrations or high pitched noises 2 Open the drain valves to empty the air tank at least once per day Weekly maintenance 1 Clean the air filter weekly Replace it with a new one after 500 hours of use 2 Open the safety valve to ensure that it is operational 3 Ensure that the pressure switch and check valve are operating normally 4 Inspect all screws and connections and tight...

Страница 9: ...er 27 Leading out Line Guard Circle 46 Support II 65 Cushion Foot 9 Cylinder Obturating Ring 28 Rotor Pin 47 1 4 Quick Connect 66 Washer 10 Cylinder Head Obturating Ring 29 Motor Screw 48 unloading Nut 67 bolt 11 Cylinder Head 30 Spring Washer 49 unloading Pipe 68 Foot 12 Cylinder Head Screw 31 Stator 50 Check Valve 69 Washer 13 Connecting Hose Obturating Ring 32 Lock Nut 51 exhaust Nut 70 Nut 14 ...

Страница 10: ... Wire 7 Pressure Plate Screw 27 Leading out Line Guard Circle 47 Power Cord with Plug 8 Cylinder 28 Motor Screw 48 Nut 9 Cylinder Obturating Ring 29 Spring Washer 49 Washer 10 Cylinder Head Obturating Ring 30 Stator 50 Cushion Foot 11 Cylinder Head 31 Lock Nut 51 Washer 12 Cylinder Head Screw 32 bearing 52 bolt 13 Connecting Hose Obturating Ring 33 Rotor 53 bolt 14 Connecting Hose 34 Safety Valve ...

Страница 11: ...re Switch 7 Pressure Plate Screw 27 Leading out Line Guard Circle 47 Capacitor 8 Cylinder 28 Rotor Pin 48 Capacitor Cover 9 Cylinder Obturating Ring 29 Motor Screw 49 Check Valve 10 Cylinder Head Obturating Ring 30 Spring Washer 50 uploading Pipe 11 Cylinder Head 31 Stator 51 exhaust Pipe 12 Cylinder Head Screw 32 Lock Nut 52 Tank 13 Connecting Hose Obturating Ring 33 Rotor 53 Handle Cover 14 Conn...

Страница 12: ...ing 29 Holding Screw 49 Air Filter 69 Cushion Foot 10 Plate Pinch 30 Cheese Head Screw 50 Support II 70 Washer 11 Pressure Plate Screw 31 Crank Case 51 1 4 Quick Connect 71 bolt 12 Cylinder 32 Leading out Line Guard Circle 52 electromagnetism 72 bolt 13 Cylinder Obturating Ring 33 Motor Screw 53 Connecting Cord 73 Capacitor 14 Cylinder Head Obturating Ring 34 Spring Washer 54 Check Valve 74 Capaci...

Страница 13: ...k Case 45 Pressure Gauge 64 bolt 8 Cylinder 27 Leading out Line Guard 46 Connecting bar 65 Power Cord with Plug 9 Cylinder Obturating Ring 28 Rotor Pin 47 Safety Valve 10 Cylinder Head Obturating Ring 29 Motor Screw 48 Pressure Switch 11 Cylinder Head 30 Spring Washer 49 Capacitor 12 Cylinder Head Screw 31 Stator 50 Capacitor Cover 13 Connecting Hose Obturating 32 Lock Nut 51 Check Valve 14 Connec...

Страница 14: ...sor n Owner s Manual n Air Filter Assembly n Attach the air filter to the top left side of motor head Screw air filter into the motor head model 6310 package contents n Air Compressor n Owner s Manual n Air Filter n Wheel Assembly kit Assembly n Attach the air filter to the top rear side of the motor head Screw air filter into the motor head n Install the wheel assembly as follows 1 Slide bolt 53 ...

Страница 15: ...particulates are in the air This will damage the motor and impair proper operation ImportAnt Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasi...

Страница 16: ...lic material and is able to function without lubrication for a long time n Compressed air discharges in the air tank A pressure meter displays the pressure inside the tank When the pressure inside the tank rises to 8 bar the power is automatically cut off by the pressure control switch When the pressure inside the tank lowers to 6 bar the power is turned back on by the pressure control switch This...

Страница 17: ... burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head ...

Страница 18: ... gasoline or alcohol Always keep parts clean from dirt and dust for better performance Adjusting the pressure Switch The pressure switch is used to control the automatic stop and start function of the air compressor ensuring the correct pressure of the compressed air in the air tank is maintained If the pressure of the compressed air in the air tank is found not to be in the standard range set by ...

Страница 19: ...es not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down use heavy duty extension cords ensure that the...

Страница 20: ...l Pressure Control Meter 2 2 2 universal Quick Connectors 2 2 1 Thermal Overload Protector yes yes yes dimensions Length 19 3 inches 49 0 cm 17 3 inches 43 9 cm 23 6 inches 59 9 cm Width 16 9 inches 43 0 cm 17 0 inches 43 2 cm 13 3 inches 33 8 cm Height 19 6 inches 50 0 cm 20 0 inches 50 8 cm 24 0 inches 60 9 cm Weight 64 lbs 29 0 kg 4610 53 lbs 4610A 44 lbs 49 lbs 22 kg 3010 1610A 1675A 1650A 3 8...

Страница 21: ...ific legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties tha...

Страница 22: ...itions or in applications not recommended by California Air Tools Inc 7 Normal wear 8 The use of accessories or attachments not recommended by California Air Tools Inc 9 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the en...

Страница 23: ...of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price ____________________...