![Calian SatService sat-nms LF20 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/calian/satservice-sat-nms-lf20/satservice-sat-nms-lf20_user-manual_3406436029.webp)
System
Contact
The unit replies to MIB-II sysContact requests with the text entered at this
place.
Access
Control
User password
Here you can define the password for the 'user' login. Default password is
'user'. When you are logged in as 'user' you are only able to change the
parameters on the 'Master Ch.' And the 'Slave Ch.' page. All the other
parameters can only be changed when you are logged in as 'admin'
Admin
password
Here you can define the password for the 'admin' login. Default password
is 'admin'. When you are logged in as "admin" you are only able to
change all the parameters of the unit.
3.5 Local operation LFTX, LFRX, LFSW Card
All available cards can also local at the frontpanle controlled by setting the RM/LC DIP-switch in
the LC position.
Please keep in mind that, if the switch is in the LC position, it is not possible, to change the
parameters of this card via remote Interface (IP, RS232, SNMP). If you switch to local the local
setting of the gain, DC out, switch position will taking in acount. If you switch back to remote the
local settings will transfer to the MNC settings.
3.5.1 Local operation LFTX Card
The following picture shows you the front view of a LFTX card.
Depending on the card configuration, the 'Opto Out' connector is an E2000 or a FC/APC
connector. Connect here the optical fibre to transmit the optical signal.
The following indicator LED's are located on the cards front panel:
Parameter
Description
LD
This (green) LED shows the state of the TX laser diode. The LED turns on, if
the laser diode is working.
PS
The (green) PS-LED displays the power supply state of the card. The LED is
on, if the power supply of the card is working.
Max
The (yellow) Max-LED turns on, if the RF input level is above the
recommended level.
RFmax Alarm level: typ. -10dBm (-11...-5dBm)
Min
The (yellow) Max-LED turns on, if the RF input level is below the
recommended level.
RFmin Alarm level: typ. -23dBm (-25...-20dBm)
(C) 2021, SatService GmbH
www.satnms.com
LF20-UM-2107 Page 28/43