CALI alumLEDs ALS500T-RMW-MI Скачать руководство пользователя страница 3

CALIFORNIA ACCENT LIGHTING, INC.

2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

1 / 29 / 2021 / Rev 2

Page 3 of 16

ALS

500T-RMW-MI

INSTALLATION INSTRUCTIONS

Diagram of Assembly (Hanging Bracket Assembly)

Wall Stud

Rail Bracket

Hex Head Screw

(8-32 x 2”)

Hex Screw Channel

Hard Ceiling

Lock Washer

Connector Block

Lens

Hex Nut

1/8” Mud

Hanging Bracket Arm

Trim Retention Spring

Mud-In Ceiling Trim

5/8” Drywall

1/8” Mud

Wall Trim

Reflective Film

Tie Wire

DIAGRAM OF ASSEMBLY

1.39”

5.47”

1.38”

3.27”

3.60”

Max. Height

DIMENSIONS

Содержание alumLEDs ALS500T-RMW-MI

Страница 1: ...d 24VDC Output Voltage To calculate driver size determine Watts per Foot Example 4W per Foot Determine Length in Feet Example 20 To calculate Load Multiply Watts per Foot x Length in Feet Example 4W x...

Страница 2: ...Power Source To Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last se...

Страница 3: ...t prior notice 1 29 2021 Rev 2 Page 3 of 16 ALS500T RMW MI INSTALLATION INSTRUCTIONS Diagram of Assembly Hanging Bracket Assembly Wall Stud Rail Bracket Hex Head Screw 8 32 x 2 Hex Screw Channel Hard...

Страница 4: ...nds of runs 8 6 15 16 Projected Location of Hard Ceiling 5 8 Drywall 5 8 Drywall Wall Stud Ceiling Line 1 16 Ceiling Line 4 Top of drywall Mark Wall Stud 1 16 Ceiling Line Mount Wall Trim Install conc...

Страница 5: ...for details 13 If applicable position the driver in the center of luminaire and secure using set screws by others Do not mount drivers between luminaires Note Driver size and location of mounting hol...

Страница 6: ...ight to make changes or withdraw specifications without prior notice 1 29 2021 Rev 2 Page 6 of 16 ALS500T RMW MI INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Assembly 5 8 Drywall 1 8 M...

Страница 7: ...6 above ceiling line Note Drywallers must hang drywall to the specifications Only cut if necessary 2 Mark locations along Wall Trim extrusion where it will be mounted to wall studs then drill holes as...

Страница 8: ...ve been mounted Note Refer to steps on page 12 for details 12 Install Ceiling Trim after all luminaires have been mounted and connected Note Follow the steps on page 13 to install Ceiling Trim 13 Hard...

Страница 9: ...nnecting luminaire to power source Refer to page 15 for continuity test step by step 17 Verify driver wire colors from wiring diagram then connect luminaires to power source Drivers used for this prod...

Страница 10: ...et Rail Bracket ALS500T RMW 6 8 Hanging Bracket Rail Bracket For luminaires 1 long use 1 Rail Bracket and 2 Hanging Brackets Install 2 Hanging Brackets 2 from each end of 1 Rail Bracket Align the 1 Ra...

Страница 11: ...1 5 Aircraft Cable Assembly 4 ALS500T RMW 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire N...

Страница 12: ...le Block to meet the Female Block Tighten Allen Screws using provided Allen Wrench to close the gap until luminaires meet Only tighten screws until extrusion edges meet with no gaps Over tightening sc...

Страница 13: ...between trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut...

Страница 14: ...URES MAINTENANCE SPECIFICATIONS REFLECTANCE 550NM 97 5 0 8 ASTM E1164 L VALUE 98 9 ASTM E308 A VALUE 0 35 0 25 ASTM E308 B VALUE 0 90 0 30 ASTM E308 GLOSS 60 5 0 ASTM D2456 THICKNESS 205 m 15 Ono Sokk...

Страница 15: ...ath is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify the malfunction in the line If there is no conductive path the multimeter w...

Страница 16: ...ctory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a ra...

Отзывы: