Calex CMM17 Скачать руководство пользователя страница 16

6-1

Parts

Cause

Diagnosis

Remedy

Fuse blows

Defective primary

Check continuity of the primary switch terminals with

Replace the primary

out when

interlock switch

wire removed using a multimeter. If there is continuity

interlock switch

door is

ary winding.

between switch terminals when door is opened,

opened.

the switch is defective.

Defective interlock 

Check continuity of the monitor switch terminals

Replace the interlock

monitor switch

with wire removed by using a multimeter.

monitor switch

If there is continuity between switch terminals
when the door is closed, the switch is defective.

Fuse is

Layer short of the

The fuse will not blow right away, but if it blows in a

Replace H. V. Transformer

open.

secondary coil of

few seconds, then there is a layer short.

H. V. Transformer

If the fuse blows with H. V. Trans secondary open, the
transformer may be faulty.

1) Fuse blown out

Check fuse.

Replace the fuse.

2) Poor contact of

Check continuity of power supply cord. Also check

Adjust or replace the

power cord

whether the power cord is securely wired.

power supply cord.

3) Defective lamp

The fan motor rotates, but lamp does not light.

Replace the lamp.

Oven lamp

4) Defective timer

Check the terminals of timer for continuity,

Replace the timer.

does not

contacts

turning the timer knob ON and OFF repeatedly.

light.

5) Thermal cutout

In this case the oven lamp and fan do not

Replace the

S/W open

turn on

thermal cutout S/W

1) Defective

If 220~230V is found at motor terminals, the motor

Replace the motor.

Fan does

fan motor.

should be replaced.

not operate.

2) Defective con-

The oven lamp does not light and fan motor

Replace the timer.

tacts of timer

does not operate.

NOTE

Interlock monitor switch must be replaced when the fuse is blown out.

WARNING FOR HIGH VOLTAGE

4000 VOLTS EXIST AT THE HIGH VOLTAGE AREA. DO NOT OPERATE THE OVEN WITH CABINET PARTS REMOVED. DO NOT
REMOVE THE CABINET PARTS IF THE POWER SUPPLY CORD IS PLUGGED IN THE WALL OUTLET. UNPLUG THE POWER CORD
BEFORE SERVICING.

6-1 Electrical Malfunction

6. Troubleshooting

Содержание CMM17

Страница 1: ...25 750W 112 225 0 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 1 Precaution 2 Statements 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Troubleshooting 7 Exploded Views and...

Страница 2: ...tion within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted component...

Страница 3: ...ck monitor switch 12 If the fuse is blown by the Interlock Monitor Switch Replace all of the following at the same time Primary door sensing switch and power relay as well as the Interlock Monitor Swi...

Страница 4: ...e negative terminal of the high voltage capacitor to to the oven chassis Use a screwdriver 3 High voltage is maintained within specified limits by close tolerance safety related components and adjustm...

Страница 5: ...50Hz AC POWER CONSUMPTION 1300W OUTPUT POWER FROM112W TO 750W 6 LEVEL POWER IEC 705 TEST PROCEDURE OPERATING FREQUENCY 2450MHz TIMER 60 MINUTES COOLING METHOD COOLING FAN MOTOR MAGNETRON OM75S 31 OUT...

Страница 6: ...3 Operating Instructions 3 1 Control Panel 3 1 375 525 750W 112 225 0 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 DEFROST...

Страница 7: ...o 100 maximum by turning COOKING POWER CONTROL knob 3 Set the time to 4 to 5 minutes by turing TIMER knob Important If any problem is experienced in the operation of the oven please refer to the secti...

Страница 8: ...2W 3 5 Adjusting the Cooking Time During Cooking Stopping the Cooking Adding Extra Time To stop the cooking Press Temporarily Open Door To resume cooking close the door Completely Turn the TIMER knob...

Страница 9: ...unt the magnetron gasket in the correct position and make sure the gasket is in good condition 1 Discharge the high voltage capacitor 2 Disconnect all the leads 3 Remove the mounting bolts 4 Reconnect...

Страница 10: ...areful when handling Door C because it is fragile Following the procedure as shown in the figure insert and bend a thin metal plate between Door E and Door A until you hear the tick sound 1 Insertion...

Страница 11: ...properly check if any other part such as the control circuit board blower motor or high voltage transformer is defective 4 4 Replacement of Fuse 4 5 Replacement of Drive Motor Disassembly Reassembly S...

Страница 12: ...rom the transformer terminals and check continuity 2 Normal resistance readings should be as follows Secondary Approx 131 5 Filament Approx 0 Primary Approx 2 29 Room temperature 20 C Magnetron Antenn...

Страница 13: ...the interlock monitor switch all together Then follow the adjustment procedures below After repair and adjustment be sure to check the continuity of all interlock switches and the interlock monitor sw...

Страница 14: ...sts with accurate equipment 1 Fill the one liter glass vessel with one liter of water 2 Stir water in glass vessel with thermometer and record glass vessel s temperature as T1 10 1 C 3 After moving th...

Страница 15: ...justment and repair of a radiarion preventing device make a repair record for the measured values and keep the data 2 If the radiation leakage is more than 4 mW cm2 after determining that all parts ar...

Страница 16: ...contact of Check continuity of power supply cord Also check Adjust or replace the power cord whether the power cord is securely wired power supply cord 3 Defective lamp The fan motor rotates but lamp...

Страница 17: ...ective If the timer does not operate with 220 230V applied to the Replace timer Timer does timer motor terminals the timer motor amy be faulty not operate 2 Defective The lamp does not light Replace t...

Страница 18: ...ontinuity of primary coil and secondary Replace the H V Trans coil If there is no continuity H V Transformer is H V Transformer former defective 7 Shorted H V Check the continuity of capacitor Replace...

Страница 19: ...ews and Parts List 7 1 Main Exploded View M1 M2 M3 M4 M5 M12 M11 M6 M7 M8 M13 M30 M9 B2 B3 B4 B1 M10 M21 M23 M24 M25 M26 M27 M28 M29 M15 M17 M16 M19 M18 M14 M22 M20 D3 D2 D1 D7 D8 D4 D5 D6 D9 D10 C6 C...

Страница 20: ...IR PP TB53 T1 7 WHT 64G M745 1 M14 DE66 90013A LEVER DOOR POM F20 01 NTR MW5630T 1 M15 DE26 10121B TRANS H V SHV 745EC1 230V 50HZ KEC 2230V 1 M16 DE61 50106A BRACKET HVC SECC T0 8 W31 L125 8 1 M17 250...

Страница 21: ...1 7 3 Assembly Door Parts List Exploded Views and Parts List Ref No Parts No Description Specification Q ty Remarks C 1 DE66 20171A BUTTON PUSH ABS WHT G643C 1 C 2 DE61 70076A SPRING BUTTON HSWR PI0 6...

Страница 22: ...12 TOOTHED 2 CN BOX DE60 10082H SCREW A 2S 4X12 TOOTHED 1 CV AIR DE60 10082H SCREW A 2S 4X12 TOOTHED 2 MO FAN DE60 10082H SCREW A 2S 4X12 TOOTHED 5 PN OUT DE60 10098A SCREW ASSY TAP TITE PH TC M4X8 SW...

Страница 23: ...OR LATCH S W 1 0mH NO NO NO NO COM COM BRN WHT BRN BLU ORG BLK BRN WHT BLU ORG BRN COM BRN 230V OV 21V BRN BRN BRN BRN BLU T C O CAVITY TIMER S W SECONDARY S W INRUSH S W BLU BLU BLU BLU BLK BLU BLU B...

Отзывы: