CAUTION: 

If the DISCAL

®

 valve is not installed, commissioned and 

 

 maintained properly, according to the instructions contained in this

 

 manual, it may not operate correctly and may endanger the user.

CAUTION: 

Make sure that all the connecting pipework is water tight.

CAUTION: 

When making the water connections, make sure that the 

pipework connecting the DISCAL

®

 is not mechanically over-stressed. Over 

time this could cause breakages, with consequent water losses which, in turn, 
could cause harm to property and/or people.

CAUTION: 

Water temperatures higher than 100°F (38°C) can be dangerous. 

During the installation, commissioning and maintenance of the DISCAL

®

 

valve, take the necessary precautions to ensure that such temperatures do 
not endanger people.

Leave this manual for the user

SAFETY INSTRUCTION

This safety alert symbol will be used in this manual to draw attention to safety related 

instructions. When used, the safety alert symbol means. 

ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED! FAILURE TO 

FOLLOW THESE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD.

CAUTION: 

All work must be performed by qualified personnel trained in the 

proper application, installation, and maintenance of systems in accordance 

with all applicable codes and ordinances.

FLOW-CONTROL 

STYLE

TYPE OF 

SOLDER

MAXIMUM LIMITATIONS

PRESSURE PSI TEMPERATURE °F

SWEAT

95-5

Tin-Antimony

150

250

50-50 tin-Lead

125

150

60-40 tin-Lead

75

250

Working Pressure & Temperature Limits

(Solder Type Limits Per ASTM Std. B16.18-1979)

3

Содержание DISCAL 551 Series

Страница 1: ...check 551 series DISCAL air separator for horizontal pipes in brass with drain Sizes 1 1 1 2 NPT female 1 1 1 2 sweat A without service check valve AC with service check 551 series DISCAL air separato...

Страница 2: ...ze 1 inch 4 size 1 inch 5 1 8 vertical 3 4 and 1 sweat drain valve 1 2 NPT female Steel air separator Materials body epoxy resin painted steel internal element 304 stainless steel seal EPDM air vent f...

Страница 3: ...DISCAL valve take the necessary precautions to ensure that such temperatures do not endanger people Leave this manual for the user SAFETY INSTRUCTION This safety alert symbol will be used in this man...

Страница 4: ...40 45 60 70 80 90 120 140 160 180 250 400 450 300 350 600 700 800 900 3 3 4 6 6 4 5 1 2 1 4 1 6 1 8 2 69 83 97 111 125 2000 1200 1400 1600 1800 4 3 5 5 12 10 8 4 3 4 0 3 5 3 0 2 7 2 2 0 27 0 25 0 22 0...

Страница 5: ...oints where the formation of micro bubbles is greatest DISCAL air separators for horizontal pipes must be installed vertically Flow direction of the DISCAL air separator is bidirectional flow in eithe...

Страница 6: ...m sticking due to accumulating 6 6 5 5 3 4 4 3 6 5 4 59829 residue in the flowing fluids even when the DISCAL air separator is not installed perfectly vertical A replacement air vent assembly for the...

Страница 7: ...6 5 5 3 4 6 4 4 3 6 4 4 7...

Страница 8: ...aukee WI 53208 T 414 238 2360 F 414 238 2366 Accessories Item Code Description 561402A Check valve for expansion tanks 1 2 NPT connections R59681 Hydroscopic safety vent cap 562100 Small anti vacuum v...