This dual check backflow preventer with intermediate atmospheric 
vent is designed to protect drinking water systems from the return, 
caused by backsiphonage or backpressure, of contaminated fluids.

The Caleffi 573 series FlowShield™ DuC-AV is certified by ICC-ES 
to be in compliance with the International Plumbing Code (IPC), 
International Residential Code (IRC), Uniform Plumbing Code (UPC), 
and standards ASSE 1012-2021, and CSA B64.3-94. Additionally, 
it is also complies with NSF/ANSI/CAN 372, low lead, as certified 
by ICC-ES, Drinking Water System Components – Lead Content 
Reduction of Lead in Drinking Water Act, California Health and Safety 
Code 116875 S.3874, Reduction of Lead in Drinking Water Act.

Product range

573 Series  FlowShield DuC-AV 
dual check backflow preventer with atmospheric vent                        
 

size 1/2”- 3/4” NPT female threaded connection with union

 size 

1/2” sweat connection with union

 size 

1/2" press connection with union 

Technical specifications

Connections:                                             

1/2”- 3/4” NPT female with union

 

1/2” SWT with union

 

1/2" press with union

Materials:   Body:                                                                         

low lead brass

 

Filter: 

stainless steel

                Check valve:                                                             

PSU

                 Check valve stem:                                      

brass

                Diaphragm:                                                                

peroxide-cured EPDM

             

Seals:                                                                           

peroxide-cured EPDM

Maximum working pressure:                                              

175 psi (12 bar)

Maximum working temperature:                                        

210°F (99°C)

Emergency back pressure temperature: 

250°F (121°C)

Medium:                                                                              

water

Certified to:                                                        ASSE 1012-2021, by ICC-ES, file PMG-1359.

                                                                                                  CSA B64.3-94, file 219199.

                                             NSF/ANSI/CAN 372-2011, Drinking Water System Components-Lead Content 

Reduction of Lead in Drinking Water Act, California Health and Safety Code 116875

 S.3874, Reduction in Drinking Water Act, as certified by ICC-ES, file PMG-1360.

1

ASSE 1012

US

C

38517.10

© Copyright 2023 Caleffi

www.caleffi.com

FlowShield

 DuC-AV 

Backflow preventer with intermediate atmospheric vent

573 Series

Содержание 573 Series

Страница 1: ...ric vent size 1 2 3 4 NPT female threaded connection with union size 1 2 sweat connection with union size 1 2 press connection with union Technical specifications Connections 1 2 3 4 NPT female with u...

Страница 2: ...echanically over stressed Over time this could cause breakages with consequent water losses which in turn could cause harm to property and or people Caleffi shall not be liable for damages resulting f...

Страница 3: ...ci pourrait causer des ruptures avec pour cons quence des pertes en eau qui leur tour peuvent causer des dommages la peopri t et ou les gens Caleffi ne pourra etre tenue responsable des dommages resul...

Страница 4: ...4 Flow rate graph 10 2 5 10 5 20 50 Dp psi G l min gpm 20 10 5 psi bar 20 1 0 5 10 2 5 15 1 0 52 0 3 Cv 0 7 VENT p psi p psi bar G l min gpm...

Страница 5: ...arrow on the valve body It also must be installed with one isolating valve and a strainer upstream and one isolating valve downstream The 573 Series FlowShield DuC AV backflow preventer must be instal...

Страница 6: ...s 1 2 S N VENT Heating system application BACKFL OW PRE V Series 573 Sizes 1 2 S N VENT Field testing installation SUPPLY Inlet test valve Upstream shut off valve Y strainer Upstream test valve 573 se...

Страница 7: ...ightness of the internal second check valve When backpressure is applied to the downstream side of the valve the internal second check valve must close back drip tight on its seat a Close shutoff valv...

Страница 8: ...8 NOTES Caleffi North America Inc 3883 West Milwaukee Road Milwaukee WI 53208 T 414 238 2360 F 414 238 2366 09 2023 For Technical Support call 1 414 338 6338 or email techsupport us caleffi com...

Отзывы: