background image

Function

The backflow preventer with atmospheric vent is designed to protect 
drinking water systems from the return, caused by backsiphonage or 
backpressure, of contaminated fluids.

The Caleffi 573 series Is certified by ICC-ES to be in compliance with 
the International Plumbing Code (IPC), International Residential Code 
(IRC), Uniform Plumbing Code (UPC), and standards ASSE 1012-
2009, and CSA B64.3-94. Additionally, it is also certified by ICC-ES 
to be in compliance with standard NSF/ANSI 372-2011, Drinking 
Water System Components – Lead Content Reduction of Lead 
in Drinking Water Act, California Health and Safety Code 116875 
S.3874, Reduction of Lead in Drinking Water Act.

Product range

573 series  backflow preventer with atmospheric vent                        
 

size 1/2”- 3/4” NPT female threaded connection with union

 

size 1/2” sweat connection with union

 

size 1/2" press connection with union

Backflow preventer with intermediate atmospheric vent

38517.06

Installation, commissioning and servicing instructions

Technical characteristics

Connections:                                             

1/2”- 3/4” NPT female with union

 

1/2” SWT with union

 

1/2" press with union

Materials:   Body:                                                                         

low lead brass

 

Filter: 

stainless steel

                Check valve:                                                             

PSU

                 Check valve stem:                                      

brass

                Diaphragm:                                                                

peroxide-cured EPDM

             

Seals:                                                                           

peroxide-cured EPDM

Maximum working pressure:                                              

175 psi (12 bar)

Maximum working temperature:                                        

210°F (99°C)

Emergency back pressure temperature: 

250°F (121°C)

Medium:                                                                              

water

Certified to:                                                       

CSA B64.3-94 and ASSE 1012-2009

 

NSF/ANSI 372-2011, Drinking Water System Components-Lead Content

 

Reduction of Lead in Drinking Water Act, California Health and Safety 

Code 116875 S.3874, Reduction in Drinking Water Act, certified by ICC-ES, file PMG-1360.