background image

VBus

®

/USB interface adapter

© Caleffi_10077_VBus/USB_monen.ind

d

|

VBus

®

/USB interface adapter

The VBus

®

/USB interface adapter is the interface between 

the controller and a personal computer. With its standard 
mini-USB port it enables a fast transmission of system data 
for processing, visualising and archiving as well as the pa-
rametrisation of the controller via the VBus

®

. A full version 

of the ServiceCenter software is included.
The interface adapter is designed for the connection to 
controllers equipped with the VBus

®

.

 

• for the connection of a PC with a USB port to a 

controller with a VBus

®

 

• logging of measured data on the PC by means 

of the included RSC software

 

• evaluation and visualisation of system data pos-

sible with a spreadsheet software

 

• remote parametrisation of the controller

 

• no external power supply required

 

• USB 1.0 and 2.0 compatible

1.  Overview

2.  Mounting

The unit must only be located in dry interior locations. It 
is not suitable for installation in hazardous locations. The 
interface adapter is light and small enough to not require 
any form of mounting. It can be placed directly on the desk 
or on a system component (pay attention to the allowed 
ambient temperature!).
Four self-adhesive, skid-proof rubber pads are included with 
the adapter. If necessary, these can be affixed to the corre-
sponding molds on the base part of the housing to ensure a 
secure placement of the device without wall mounting.
If desired, the interface adapter can be mounted to a wall:

 

Î

Mark the desired hanging position on the wall

 

Î

Drill and prepare the hole with a wall plug and screw

 

Î

Hang the device onto the screw

 

Î

Mark the position for the mounting screw (centres 
70 mm)

 

Î

Drill and prepare a hole with a wall plug

 

Î

Hang the device and fasten it by means of the second 
screw

For wall mounting, opening the housing is not required. 
Opening the housing is only required for access to the 
terminals.

 

Î

To open the housing, unscrew the cover screw and pull 
off the upper part of the housing

 

Î

To close the housing again, relocate the upper part of 
the housing and refasten the cover screw

ATTENTION! ESD damage!

Electrostatic discharge can lead to da-
mage to electronic components!

 

Î

Take care to discharge properly 
before touching the inside of the 
device. To do so, touch a grounded 
surface such as a radiator or tap!

Front view

Back view

Opening for the 
mounting screw

Hanging

Molds for the 
rubber pads

Cover screw

Upper part of 
the housing

Base part of  
the housing

Отзывы: