Commissioning:
Flow unit
Litres/hour
Energy unit
kWh
Antifr. type
Water
Flow unit
Selection: Litres/hour, Gal./minute
Factory setting: Litres/hour
Î
Adjust the desired flow rate unit.
Completing the commissioning menu:
When the last menu item of the commissioning menu (Save)
has been selected, a security inquiry appears. If the inquiry
is confirmed, the adjustments will be saved. All adjustments
made during commissioning can, if necessary, be changed
later on in the corresponding menus.
Commissioning:
Energy unit
kWh
Antifr. type
Water
Antifreeze
40 %
Energy unit
Selection: kWh, BTU
Factory setting: kWh
Î
Adjust the desired energy unit.
Commissioning:
Energy unit
kWh
Antifr. type
Water
Antifreeze
40 %
antifr. type
Selection: Water, Propylene, Ethylene, Tyfo LS
Factory setting: Water
Î
Adjust the heat transfer fluid used in the system.
Commissioning:
Antifr. type
Propylene
Antifreeze
40 %
Volume/Imp.
1.0 L/I
Commissioning:
Antifreeze
40 %
Volume/Imp.
1.0 L/I
Save
Volume/Imp.
Adjustment range: 0.1 ... 99.9 L/I
Factory setting: 1.0 L/I
Î
Adjust the impulse rate of the flowmeter or flow rate
sensor respectively.
Commissioning:
Antifr. type
Propylene
Antifreeze
40 %
Volume/Imp.
1.0 L/I
antifreeze
Adjustment range: 20 ... 70 %
Factory setting: 40 %
Available only if Antifr. type is set to Propylene or Ethylene.
Î
Adjust the antifreeze ratio of the heat transfer fluid
used in the system.