background image

2

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

AVOIDING THE RISK TO CHILDREN

DANGER:

RISK OF CHILD DROWNING.

Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot

use a spa unless they are supervised at all times.

WARNING:

• To reduce the risk of injury, do not permit children to use this spa unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

DO:

• Make sure you always lock the child resistant locks after using the spa for your children’s safety. Every Caldera

®

spa is equipped with a locking cover that meets

the ASTM F1346-91 Standard for Safety Covers.

• Test the water temperature with your hand before allowing children to enter the spa to be sure that it’s comfortable. Children are especially sensitive to hot water.
• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering, or exiting the spa.

DON’T:

• Allow children to climb onto the spa cover.
• Allow children to have unsupervised access to the spa.

AVOIDING THE RISK OF ELECTROCUTION

Risk of electrocution

• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type cable is not used, or if

improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG solid copper bonding

conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit
as needed to comply with local requirements.

WARNING:

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury due to electrocution.
• Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection. To ensure proper operation of this important safety device, test

according to the following instructions per electrical configuration.

230 volt, permanently installed models:

• A ground terminal is provided on the terminal block located inside the control box. To reduce the risk of electric shock, connect this terminal to the grounding

terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must be equivalent in size to the circuit conductors
supplying the equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box for bonding to local ground
points. To reduce the risk of electric shock, this connector should be bonded with a No. 10 AWG solid copper wire to any metal ladders, water pipes, or other
metal within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5
feet (1.5 m) from the spa.

• Your spa is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.
• Your spa uses ground fault circuit interrupters in the electrical subpanel. Before each use of the spa and with the unit operating, push the TEST button on each

breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on.
The switch should then stay on. If either of the interrupters does not perform in this manner, it is an indication of an electrical malfunction and the possibility of
an electric shock. Disconnect the power until the fault has been identified and corrected.

DANGER: RISK OF ELECTRICAL SHOCK

• Install spa at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of a metal surface if each metal surface is permanently connected

by a minimum No. 10 AWG solid copper conductor attached to the wire ground connector on the terminal box that is provided for this purpose if in accordance
with National Electrical Code ANSI/NMFPA70-1993.

• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a spa. Failure to maintain a safe distance may

result in death, or serious personal injury due to electrocution, if the appliance should fall into the spa.

• Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components.

SAFETY INFORMATION

Содержание Moorea

Страница 1: ...MooreaTM Hawaiian Martinique Kauai Paradise Series Owner s Manual...

Страница 2: ...LEPHONE ________________________________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties per...

Страница 3: ...IONS Locking Features 19 Main Control Panel Buttons and Display 20 EQUIPMENT COMPARTMENT Jet Pump Side 22 Controls Side 23 MAINTENANCE Filter Maintenance 24 Filter Cartridge Removal and Cleaning Instr...

Страница 4: ...ructions per electrical configuration 230 volt permanently installed models A ground terminal is provided on the terminal block located inside the control box To reduce the risk of electric shock conn...

Страница 5: ...use the spa Health problems affected by spa use Pregnant women should consult a physician before using spa Persons suffering from obesity or with a medical history of heart disease low or high blood p...

Страница 6: ...r authorized Caldera dealer Many problems can easily be diagnosed over the telephone by an Authorized Service Technician SAVE THESE INSTRUCTIONS SITE PREPARATION You probably have a spot picked out fo...

Страница 7: ...r regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refill your spa with fresh water on a regular schedule and in accordance with this owner s manual...

Страница 8: ...ersaSsage Jet 7 Euphoria Jet 8 Grab Rail 9 Diverter Valve 10 Drain 11 Light 12 Ozone Jet 13 Control Panel 14 Pillow 15 Filter Compartment 16 Water Fall 17 Water Fall Valve 1 1 1 3 5 6 5 8 10 10 11 13...

Страница 9: ...t 6 MagnaTM Jet 7 Euphoria Jet 8 Diverter Valve 9 Drain 10 Light 11 Ozone Jet 12 Control Panel 13 Pillow 14 Filter Compartment 15 Grab Rail 16 Waterfall 17 Waterfall Valve 1 3 4 4 4 10 7 13 13 13 13 2...

Страница 10: ...re Sensor 4 MagnaSsageTM Jet 5 MagnaTM Jet 6 VersaSsage Jet 7 Grab Rail 8 Diverter Valve 9 Drain 10 Light 11 Ozone Jet 12 Control Panel 13 Pillow 14 Filter Compartment OVERHEAD VIEW PARADISE MARTINIQU...

Страница 11: ...al Jet 3 Euro Pulse Jet 4 VersaSsage Jet 5 Grab Rail 6 Diverter Valve 7 Drain 8 Light 9 Ozone Jet 10 Control Panel 11 Pillow 12 Filter Compartment 13 Temperature Sensor OVERHEAD VIEW PARADISE KAUAI MO...

Страница 12: ...ust be attached to the LOAD neutral on the 230 volt 30 amp breaker not to the neutral bus bar in the subpanel The WHITE neutral wire coming from the breaker itself is already connected to the neutral...

Страница 13: ...y require larger gauge wire than stated ELECTRICAL INSTALLATION System Ground Terminal GRD WARNING THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONN...

Страница 14: ...ty TA to 125 ppm Calcium Hardness CH to 150 ppm then spa water pH to between 7 4 and 7 6 These procedures are listed in the Water Quality and Maintenance section OPERATION NOTE Adjusting the Total Alk...

Страница 15: ...ve located on the front interior wall counterclockwise The flow is regulated by turning the waterfall valve to the desired position AIR CONTROLS Each jet system has its own air control These allow you...

Страница 16: ...low you to regulate the force of the massage Rotate the fascia ring clockwise to reduce the force or counter clockwise to increase the force Notice that turning off the flow to some jets increases the...

Страница 17: ...in mid position activates both Jet Pump 1 Systems 1 and 2 Jet Pump 2 diverter in mid position activates both Jet Pump 2 Systems 1 and 2 PARADISE MOOREA TM Jet Pump 2 Jet System 2 Waterfall Positioned...

Страница 18: ...ge jets Jet Pump 2 Jet System 1 6 Sole Soothers Waterfall Located in Ultra Massageseat front right 3 VersaSsage jets 2 Euro Directional jets Jet Pump 2 Jet System 2 1 Euphoria jet in footwell Ultra Ma...

Страница 19: ...Jet Pump 2 Jet System 1 Located in Ultra Massagelounge front 6 Sole Soothers 2 Euro Directional jets 3 VersaSsage jets Combination Jet System Jet Pump 2 diverter in mid position activates both Jet Pu...

Страница 20: ...eat 8 Euro Directional jets 2 Euro Pulse jets Jet Pump Jet System 2 Located in Ultra Massagelounge 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Located in LumbarSsage lounge 4 Euro Direct...

Страница 21: ...nation of buttons Once enabled a lock will remain active until the specific button combination is applied to disable the lock Even if power is disconnected from the spa and soon thereafter reapplied s...

Страница 22: ...of the spa water press the TEMP Each time the button is pressed the set temperature display will decrease by one degree If the button is held down the set temperature display will decrease by one degr...

Страница 23: ...ater temperatures low enough for comfort Upon switching to the ON mode the heater will immediately shut down while the circulation pump which can add heat to the water through normal operation will re...

Страница 24: ...Included with the Optional Monarch CD Ozone Generator kit 4 Unions 5 Air Blower 6 Light 7 Temperature Sensor 8 Pump Drain Plug 1 2 3 5 2 3 3 6 1 Kauai Moorea Hawaiianand Martinique NOTE Martinique doe...

Страница 25: ...UIPMENT COMPARTMENT A B C D A Advent Control Box System B EnergyPro Circulation Pump C EnergyProFlow Through Heater D Monarch CD Ozone Generator optional E SpaGlo LED Light System optional E CONTROLS...

Страница 26: ...come lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To accomplish this follow this procedure 1 Turn off power to the spa...

Страница 27: ...a wet dry vacuum or a sponge 3 It will be necessary to remove all water from the interior plumbing 4 Remove the filter lid floating weir basket and filter cartridge Clean the filter cartridge and sto...

Страница 28: ...asives or solvents since they may damage the shell surface NEVER USE HARSH CHEMICALS Damage to the shell by the use of harsh chemicals is not covered under the warranty IMPORTANT Some surface cleaners...

Страница 29: ...d the labels carefully and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines...

Страница 30: ...sure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium low water commonly known as soft water is not recommended It...

Страница 31: ...njunction with all of the other products in this system It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an...

Страница 32: ...be no residual of silver ions present in the water eliminating them from the sanitizing process Questions How often should the Monarch Silver cartridge be replaced Answers The cartridge must be repla...

Страница 33: ...ime is simply the amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For exam...

Страница 34: ...nce program based on recognized and documented industry standards still be followed when using an ozone purification system to assure water sanitation and the highest quality purified water Cleaning t...

Страница 35: ...e extremely high High sanitizer levels can chemically burn or discolor the spa s shell or the underside of the cover Then after a period of time the sanitizer level dispensed by the floater will fall...

Страница 36: ...Available Chlorine Halogen Any one of these five elements fluorine chlorine bromine iodine and astatine MPS Monopersulfate is a non chlorine oxidizer Oxidizer The use of an oxidizing chemical is to pr...

Страница 37: ...just pH and or alkalinity to recommended range Run jet pump s and clean filter Drain and refill the spa Shock spa with sanitizer Add sanitizer Adjust pH to recommended range Shock spa with sanitizer A...

Страница 38: ...l include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions or use of the spa in an application for which it is not designed specifically us...

Страница 39: ...emperature sensor problem Heater high limit thermostat tripped Temperature set too low Spa cover improperly positioned Dirty Filter Summer Timer On Motor overload condition Control switch failure if j...

Страница 40: ...or 50 amp Single phase GFCI protected circuit Moorea Model MOA 36 75 Square feet 4 300 420 Gallons 870 Lbs 5 490 Lbs 115 Lbs per square foot 7 5 x 6 4 Martinique Model MRA 34 75 Square feet 4 300 320...

Отзывы: