19
OPERATING INSTRUCTIONS
To display the set temperature for three seconds, press either WARM or COOL. To change the set temperature while the se temperature is displayed, press WARM to
increase or COOL to decrease the set temperature. An LED between the WARM and COOL buttons will illuminate whenever the heater is activated.
Jets Control
Pressing the Jets 1 or Jets 2 button turns the single speed pump on or off. An LED above the Jets button will illuminate whenever the Jets button is activated. The
pumps automatically turn off after operating for 30 minutes.
Air Jets Control
Press the Air Jets button to start or stop the air jets. The air jets operate for 15 minutes, then automatically shut off. An LED above the Air Jets button will illuminate
whenever the Air Jets button is activated.
Light Control
Pressing the light button operates the fiber optic light as follows:
• Press
once to turn on the light and rotate the color wheel.
• Press
again to turn off the rotating color wheel while the light remains on.
• Then press
a third time to shut both the light and color wheel off.
The light automatically turns off after 6 hours of operation.
Advance Mode Control
The Mode button is used to initiate advanced panel features such as the cleanup cycle, panel lock, temperature lock, and setting the automatic fiber optic light
(optional).
AUTOMATIC OPERATIONS
System Purge
The system purge operates in the following maner:
• The air blower activates for 30 seconds.
• Jet Pump 2 runs for 1 minute.
• Jet Pump 1 runs for 10 minutes.
This system is initiated 60 seconds after the spa is powered up, then operates one time per day.
Summer Logic
The circulation pump, heater and ozone are disabled if the temperature regulating system detects that the water temperature exceeds the set temperature by 5 degrees.
The circulation pump, heater and ozone will remain disabled for the next 8 hours. After 8 hours, the functions will be enabled and remain active for the next 16 hours.
Upon completion of a 24 hour period the temperature regulating system will again compare the water remperature with the set temperature to determine if the cycle
should repeat.
Auto Heat
The heater will automatically activate if the water temperature is 20°F below the set temperature.
Fiber Optic Light
If your spa is equipped with the fiber optic light, it may be set to automatically come on for 6 hours every day. You must wait until the desired starting time before
activating the automatic mode. To activate the automatic mode, press
+
+
within 3 seconds. This will cause the fiber optic light to
illuminate for 6 hours every night at the same time. To deactivate the automatic function simply press the same buttons again.
NOTE: Automatic fiber optic light is not enabled on power-up.
Cleanup Cycle
The cleanup cycle (used for water maintenance) will activate Jet Pump 1, run for ten minutes, then automatically shut off. To activate the cleanup cycle,
press + within 3 seconds.
Auxiliary Control Panel
The auxiliary control panel, conveniently located opposite the main control panel, allows the user to activate the jets and light from inside the spa.
NOTE:
Keep in mind that the auxiliary panel will not function if the Spa Lock feature on the main control panel has been activated.