Pre-Delivery Instructions

NOTE: 

WATKINS WELLNESS

 requires that the 

CANTABRIA

 be installed on a minimum 4" (10 cm) thick reinforced 

concrete pad or structurally sound deck able to support the “dead weight” found in the spa specification chart.

WARNING

: The 

CANTABRIA

 must not be shimmed in any manner.

CANTABRIA

NOTE: All dimensions are approximate; measure your spa before making 

critical design or pathway decisions.

Configuration and location may change without notice.

108.0” (274 cm)

38” 

(97 cm)

30.25” 

(77 cm)

102.0” (259 cm)

85.125” 

(216 cm)

Cantabria

95” (241 cm)

13” 

(33 cm)

91” 

(231 cm)

4” 

(10 cm)

28.75” 

(73 cm)

(Front View)

Door Opening

Drain

(Center of Spa)

Electrical Cut-Out 

(both sides)  

3" (7.6 cm) up from 

bottom of spa

(Bottom View)

Air Vent

Do Not Block

Air Vent

Do Not Block

Air Vent

Do Not Block

Base Pan

Side Walls

Base Pan Side Walls

DOOR SIDE

Electrical Cut-Out 

(both sides)

Front Door Panel

Содержание CalderaSpas Utopia Series

Страница 1: ...___________________________ DEALER ____________________________________________________________________________ ADDRESS ___________________________________________________________________________ TELE...

Страница 2: ...n wet Proper drainage is essential to prevent a build up of water around the spa When building a new room for the spa it is recommended that a floor drain be installed The humidity will naturally incr...

Страница 3: ...ufacturer If you are interested in having a concrete slab brick surface or wood deck installed your CALDERA dealer should be able to suggest a qualified licensed contractor DELIVERY ACCESS First locat...

Страница 4: ...nstallation If your spa delivery requires the use of a crane you may be required to pay for its services at the completion of the delivery SPA DIMENSIONS Model Width W Length L Height H CANTABRIA 38 9...

Страница 5: ...easure your spa before making critical design or pathway decisions Configuration and location may change without notice 108 0 274 cm 38 97 cm 30 25 77 cm 102 0 259 cm 85 125 216 cm Cantabria 95 241 cm...

Страница 6: ...be shimmed in any manner GENEVA and NIAGARA NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions Configuration and location may change without notice...

Страница 7: ...specification chart WARNING The TAHITIAN and FLORENCE must not be shimmed in any manner 84 0 213 cm 36 91 cm 28 25 72 cm 78 25 199 cm 78 25 199 cm TAHITIAN 71 180 cm 13 33 cm 84 213 cm 4 10 cm 26 75...

Страница 8: ...d on a minimum 4 10 cm thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The RAVELLO must not be shimmed in any mann...

Страница 9: ...r until panel un clips followed by the right corner until panel un clips Clip Clip Clip 3a Light connector Turn and pull to remove 3b Logo Light connector Push in side clips and pull to remove 3 Pull...

Страница 10: ...nel to the subpanel The equipment pack requires a MINIMUM of 112 volts per line under load The grounding conductor must be at least 10 AWG Your electrician should mount the subpanel in the vicinity of...

Страница 11: ...er GENEVA TAHITIAN NIAGARA FLORENCE RAVELLO WIRING DIAGRAMS MAIN CONTROL PANEL 220 240 VAC WIRING ACCESS DOOR See page 9 for Door Panel Removal Instructions 220 240 VAC WIRING ACCESS DRAIN POWER CONNE...

Страница 12: ...only Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker Remove jumpers A from TB 1 PROVIDED WITH SPA NOTE ALL WIRING SHOULD BE COPPER Refer to NEC 250 122 tab...

Страница 13: ...emove screwdriver Install Stripped end of wire into Terminal Block Push top of screwdriver away from wire Terminal Block Insert screwdriver to engage cage clamp 4 6 1 2 3 5 3 WIRE INSTALLATION FOR CON...

Страница 14: ...Auxiliary panel functions Optional CALDERA Entertainment System Explain the safety features ______________ GFCI Heater high limit General spa operation maintenance orientation ______________ Water qua...

Страница 15: ...___________________________________________________________________ Telephone _______________________________________________________________________________ Name _____________________________________...

Страница 16: ...m 36 91 cm 100 square feet 4 000 375 gallons 1 425 liters 900 lbs 410 kg 5 080 lbs 2 315 kg 125 lbs ft 610 kg m 230 volt 30A or 20A 30A Single phase GFCI protected circuits FLORENCE 7 0 x 7 0 2 13 m x...