background image

Watkins Manufacturing Corporation

Vista, California

USA

©2010  Watkins  Manufacturing  Corporation.  Caldera  spas,  Vacanza,  Palatino,  Marino,  Aventine,  Cima,  Lina,  Monarch,  EcoTech, 

Mystique,  Euro-Pulse,  AdaptaFlo,  AdaptaSsage,  and  The  Home  Relaxation  Specialists  are  trademarks  of  Watkins  Manufacturing 

Corporation.  BaquaSpa  is  a  trademark  of  Arch  UK  Biocides,  Limited  Inc.  SPA  FROG 

®

  is  a  registered  trademark  of  King  Technology.

CAUTION: Watkins

 

Manufacturing Corporation suggests a structural engineer or contractor be consulted before the 

spa is placed on an elevated deck.

*  NOTE: The “Filled weight” and “Dead weight” of the spa includes the weight of the occupants (assuming an 

average occupant weight of 175 lbs).

Vacanza

 SerieS Spa SpecificationS

Part # 301996, Rev. C (4/10)

Palatino

(Model PLT)

7'5"

x

7'5"

38"

65 

square 

feet

4,000

400 

 

gallons

920 

 

lbs.

5,915  

lbs.

115 

lbs. per 

Square foot

230 volt, 50 amp

 

Single phase 

GFCI circuit

Marino

(Model MRN)

7'0"

x

7'0"

36"

65 

square 

feet

1,000

 

or 

4,000

360 

 

gallons

706 

 

lbs.

4,636  

lbs.

100

 

lbs. per 

Square foot

230 volt, 50 amp

 

Single phase 

GFCI circuit

Aventine

 

®

(Model AVH)

5'5"

x

5'5"

29"

35 

square 

feet

1,000

 

or

4,000

150 

 

gallons

395  

lbs.

2,020

 

lbs.

80

 

lbs. per 

Square foot

115 volt, 20 amp

 

Dedicated GFCI

 

protected cord or 

230 volt, 50 amp

 

Single phase 

GFCI circuit

Cima

™ 

(Model CIM)

6'6"

x

6'6"

35"

50 

square 

feet

5,500

280 

 

gallons

390 

 

lbs.

3,475 

lbs.

80

 

lbs. per 

Square foot

230 volt, 50 amp

 

Single phase 

GFCI circuit

Lina

 

(Model LIN)

6'6"

x

6'6"

35"

50 

square 

feet

1,000

280 

 

gallons

350 

 

lbs.

3,435 

lbs.

80

 

lbs. per 

Square foot

115 volt, 20 amp

 

Dedicated GFCI

 

protected cord or 

115 volt, 30 amp

 

Single phase 

GFCI circuit

Footprint

dimensions Height

Ef

fective

 

filter area

Heater(W

atts)

W

ater

capacity

Dry weight

Filled weight*

Dead weight* Electrical

requirements

Содержание Caldera Spa Vacanza Series

Страница 1: ......

Страница 2: ..._ SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be required for the installation of electrical circ...

Страница 3: ...Aventine 15 Cima 16 Lina 16 OPERATING INSTRUCTIONS Control Operation Palatino Marino Aventine 17 Control Operation Cima Lina 19 WATER QUALITY AND MAINTENANCE Water Terminology 21 General Information 2...

Страница 4: ...tion of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 20 amp models The GFCI is located at the end of the power cord Be...

Страница 5: ...l suction fitting There is a danger of slipping and falling Remember that wet surfaces can be very slippery Take care when entering or exiting the spa Never operate spa if the suction fittings are bro...

Страница 6: ...the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the pro...

Страница 7: ...manual and printed instructions on all water care chemical products packaging Test the water regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refil...

Страница 8: ...mproperly wired circuit will negate many of the spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical instal...

Страница 9: ...TRAL wire from the Neutral Ground Bar on the main electrical service to the WHITE NEUTRAL Panel Neutral Pigtail of the subpanel 2 Connect the 8 AWG BLACK L1 wire from the main electrical service to th...

Страница 10: ...8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main electrical service to the GROUND terminal of the...

Страница 11: ...the wiring diagram below 1 Connect the 8 AWG WHITE NEUTRAL wire from the Neutral Ground Bar on the main electrical service to the WHITE NEUTRAL Panel Neutral Pigtail of the subpanel 2 Connect the 8 A...

Страница 12: ...not feel a steady stream of water from your jets refer to the instructions for priming the pump in the SPA TROUBLESHOOTING section in the back of this manual 5 Adjust Total Alkalinity TA 80 180 ppm Ca...

Страница 13: ...ream of water from your jets refer to the instructions for priming the pump in the SPA TROUBLESHOOTING section in the back of this manual 4 Adjust Total Alkalinity TA 80 180 ppm Calcium Hardness CH 15...

Страница 14: ...aptaFlo jets 6 AdaptaSsage Jets 7 Outlet for optional ozone 8 Drain suction fitting 9 Pillow 10 Waterfall valve 11 Acquarella 12 Waterfall SPA FROG 13 Palatino Marino WARNING DO NOT SIT IN THE FILTER...

Страница 15: ...tional ozone 9 Drain suction fitting 10 Pillow 11 Grab Rail 12 SPA FROG 13 aventine 1 2 3 4 6 7 8 7 12 5 11 6 8 10 9 8 13 WARNING DO NOT SIT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting i...

Страница 16: ...or 3 Spa light 4 Drain suction fitting 5 AdaptaFlo jet 6 AdaptaSsage jet 7 Euro Directional jet 8 Euro Pulse jet 9 Outlet for optional ozone 10 lINA WARNING DO NOT SIT IN THE FILTER COMPARTMENT AREA T...

Страница 17: ...aSsage Jets in back right 2 AdaptaFlo Jets and 1 Euro Jet in right center 4 Euro Jets in footwell PALATINO MARINO Jet System 1 2 Speed Pump 8 Euro Jets in back left 2 AdaptaFlo Jets in back center Acq...

Страница 18: ...MENUS 15 AVENTINE Jet System 2 Euro Jets in back left 3 AdaptaFlo Jets in back left 2 Euro Pulse Jets in arm rests 4 Euro Jets in back right 2 AdaptaFlo Jets in back right 1 AdaptaFlo Jet in front ri...

Страница 19: ...front right 1 Euro Directional Jet and 2 Euro Pulse Jets in front left Jet System 1 2 Speed Pump 6 Euro Directional Jets and 2 Euro Pulse Jets in back left 4 Euro Directional Jets 4 Euro Pulse Jets a...

Страница 20: ...pump runs on high speed 3rd press One and Two speed jet pumps run on high speed 4th press One speed jet pump runs on high speed 5th press Both jet pumps are off Aventine Spa Model only 1st press Two s...

Страница 21: ...ctivated the filter cycle icon on the display is turned on If the temperature exceeds the set point by three degrees F for more than three hours the system will suspend the FILTER cycle and the filter...

Страница 22: ...temperature range is from 60 F 15 5 C to 104 F 40 C Temperatures of any setting may rise slightly depending on the current use and condition of your spa and on outside temperature Whenever power is di...

Страница 23: ...until the display shows xx where xx is a number from 0 12 This is the length of the filter time B Using Up 5 or Down 6 adjust the value as desired C Pressing the LIGHT button again confirms the settin...

Страница 24: ...oramines and will not alter the water s pH Pathogen A microorganism such as bacterium that cause disease pH The measure of the spa water s acidity and alkalinity The recommended pH for the spa water i...

Страница 25: ...ubstance can be identified Don t let chemicals get on surrounding surfaces or landscaping Don t use a vacuum cleaner to clean up chemical spills Never smoke around chemicals Some fumes can be highly f...

Страница 26: ...should be added to the spa water according to label instructions D If the CH is too low add CH Increaser E Once the CH is balanced it normally remains stable although the addition of more water with a...

Страница 27: ...owner s manual for start up and operation instructions The owner s manual is included with the SPA FROG starter kit It is important to follow the recommended application and maintenance programs outli...

Страница 28: ...A Sanitizing chemicals such as bromine are oxidants that kill bacteria and viruses in the water If you are using the SPA FROG system the recommended bromine level for your spa water is 1 0 2 0 ppm If...

Страница 29: ...Deposit Inhibitors As water evaporates from your spa and new water is added the amount of dissolved minerals will increase Minimize evaporation by keeping the cover on the spa whenever possible The sp...

Страница 30: ...o the spa 8 Remove the empty cup or bucket 9 Reinstall the tubing to the bottom of the ozonator 10 Close the equipment compartment door 11 Reconnect power to the spa 12 The Monarch ozone system is pra...

Страница 31: ...uildup of oils and dirt High pH Low sanitizer level Low pH Low sanitizer level Unsanitary water Free chlorine level above 5 ppm Total alkalinity and or pH too low High iron or copper in source water H...

Страница 32: ...ended in the Caldera Spa Water Maintenance program are needed to protect the user from water borne pathogens disease causing microbes and to prevent corrosion of spa components Question Why isn t wate...

Страница 33: ...the spa 5 Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying water to remove all debris possible Let the filter dry and then look for calcium deposits scaling or an...

Страница 34: ...mended DO NOT use any cleaning products 2 containing abrasives or solvents since they may damage the shell surface NEVER USE HARSH CHEMICALS Damage to the shell by the use of harsh chemicals is not co...

Страница 35: ...ended period follow steps 1 through 7 outlined in DRAINING YOUR SPA then complete the steps below IMPORTANT The following steps should protect your spa from freezing damage provided these instructions...

Страница 36: ...cal tablets in a floater acid or any other spa chemicals or spa surface cleaners which are not recommended by Watkins Manufacturing Corporation damage caused by allowing undissolved spa sanitizing che...

Страница 37: ...k for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressure switch trips frequently Contact an Authorized Service T...

Страница 38: ...Authorized Service Technician Jets weak or surging Spa water level too low Filters clogged suction screens clogged Jet nozzles closed Air valve closed Add water Clean filters Clean suction screens Ope...

Страница 39: ...s to allow the air to escape When water is present hand tighten the union Turn power back on activate the pump and check to make sure union is tight enough to keep it from leaking Re install equipment...

Страница 40: ...915 lbs 115 lbs per Square foot 230 volt 50 amp Single phase GFCI circuit Marino Model MRN 7 0 x 7 0 36 65 square feet 1 000 or 4 000 360 gallons 706 lbs 4 636 lbs 100 lbs per Square foot 230 volt 50...

Отзывы: