CalAmp 520005-1 Скачать руководство пользователя страница 2

131908/2

C+A

2

GENERAL INSTALLATION

INSTRUCTIONS FOR TRANSCEIVER

NOTE to System Operator:

California Amplifier family of Transceiver products has been designed for
installation by a licensed or qualified installer with experience in installing
wireless antennas.

NOTE to INSTALLER:

1.  Installation and operation of this family of Transceiver products require full

compliance with FCC-adopted radio frequency exposure limits. It is in the
responsibility of the installer to install these devices and their associated
antennas so that RF exposure does not exceed 1.0mW/cm

2

.  The following

table summarizes the minimum distance required to satisfy these
requirements.

Limits, Minimum

P/N

Integrated Planar (17 dBi)

Standalone (when used with 24 dBi)

520005-1

N/A

26 in. (66 cm)

520004-1

N/A

 48 in. (122 cm)

520006-1

N/A

26 in. (66 cm)

520007-2

12 in. (30 cm)

N/A

520024-2

12 in. (30 cm)

N/A

520004-2

22 in. (55 cm)

N/A

520006-2

12 in. (30 cm)

N/A

2. When installing a standalone Transceiver, orient the FCC RF exposure label

so that it is facing the front of the Antenna This is a mandatory requirement
by the FCC to comply with RF exposure compliance requirements. The
label should not be obstructed when installation is complete. This will
allow the warning label to be visible and readable. This is a mandatory
requirement by the FCC to comply with RF exposure compliance
requirements

Содержание 520005-1

Страница 1: ...nknown hazards damage and or unacceptable performance The information contained in this applications note is intended to assist the operator in developing a set of installation guidelines and operating practices for the field personnel skilled in installing roof top subscriber equipment California Amplifier accepts no responsibility for claims of injury death destruction of property or loss of tel...

Страница 2: ...llowing table summarizes the minimum distance required to satisfy these requirements Limits Minimum P N Integrated Planar 17 dBi Standalone when used with 24 dBi 520005 1 N A 26 in 66 cm 520004 1 N A 48 in 122 cm 520006 1 N A 26 in 66 cm 520007 2 12 in 30 cm N A 520024 2 12 in 30 cm N A 520004 2 22 in 55 cm N A 520006 2 12 in 30 cm N A 2 When installing a standalone Transceiver orient the FCC RF e...

Страница 3: ...owed by a short roof or chimney mount When higher gain or foliage clearance is needed then a tree mount or mast mount should be considered The following mounts are described and their general application Wall or Standoff Mount These are used in high signal density areas where antenna aesthetics is of concern It offers great flexibility in mounting angles and locations The stand off arms mount from...

Страница 4: ...pplication of brick type chimneys a dual band strap mount is best The proper strap will securely fasten the mounting bracket and antenna For wood over metal construction chimney a version of the wall mount is best Make sure the anchor bolts attach to a supporting stud member and not just the fascia board ...

Страница 5: ...pplicable specifications and drawings of the system operator This requirement includes the choice of antennas the weatherproofing of all connections all penetrations into the building and all grounding procedures both at the antenna mount and at the point of drop entry into the building INSTALLATION PLANNING In addition to meeting the highest standards of quality and workmanship another valid goal...

Страница 6: ...can affect system performance Microwave signals are highly susceptible to absorption by trees and other foliage A wireless antenna thus cannot view the transmitter from behind a tree Distant trees can also cause reception problems While they may not be visible to an installer they may still lie in the transmission path Signal fluctuations exceeding 2 dB during a survey may be an indication of dist...

Страница 7: ...FETY NOTE Aluminum ladders are not to be used for field installation or repair service Only ladders that have fiberglass rails may be used because of the possibility of contact with electrical wires or other energized conductors Ladders should be checked weekly to make sure that they are in good repair and safe working order Instructions 1 Determine the location of antenna Choose a location and he...

Страница 8: ... the scope of these instructions to recommend a method Please check with the system operator s installation guidelines for recommended procedures 6 Once inside the customer premises the cable must be run to the location of the cable modem At this location add powering by connecting the cable to the power passing side of the power inserter and plug in the power supply into an appropriate outlet Not...

Страница 9: ...131908 2 C A 9 Transceiver Planar Array Antenna Cable Modem ...

Отзывы: