
2009 Portable Spa
LTR20091000, Rev. C
Operating
Your Spa
www.calspas.com
15
Setting the Temperature Lock
To activate the temperature lock:
Press the “UP” or “DOWN” button, “TIME”, “JETS
•
1”, then the “UP” button within three seconds.
The panel will display “TEMP LOCK” when the set
temperature is locked.
To unlock the set temperature:
Press the “UP” or “DOWN” button, “TIME”, “JETS
•
1”, and then the “DOWN” button.
Circulation Pump
This is an optional feature. The circulation pump will
come on when the system is checking temperature,
during filter cycles, during freeze conditions, or when
another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end
times of each cycle are programmable. To program,
set the time as instructed above, then press “MODE/
PROG” to advance to the next setting (or to exit
after the last setting). The default filter cycles are as
follows:
The first filter cycle is automatically activated at
•
8:00 AM and operates the pump until 10:00 AM.
The “FILTER 1” indicator icon will light when filter
1 is running.
The second filter cycle is automatically activated
•
at 8:00 PM and operates the pump until 10:00 PM.
The “FILTER 2” indicator icon will light when filter
2 is running.
The pump and the ozone generator will run during
filtration. At the start of each filter cycle, the blower
will run on highest speed for 30 seconds to clean out
the air channels. The lowest speed of pump 2 and
pump 3 will run for five minutes. In the event of power
loss or shut down, the time of day will need to be
reset for filter cycles to run according to your desired
programming.
Clean up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The pump
and the ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone
generator (if installed) runs during filter cycles (except
when pump 1 is operating at high speed on a non-circ
ulating system) and during clean-up cycles. On some
systems, the ozone generator operates whenever
the pump runs. If your system is configured with the
optional ozone disable feature, the ozone generator
will turn off for one hour any time a function button
(“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44°F
within the heater, the pump automatically activates
to provide freeze protection. The equipment stays
on until four minutes after the sensors detect that
the spa temperature has risen to 45°F or higher. In
colder climates, an optional additional freeze sensor
may be added to protect against freeze conditions that
may not be sensed by the standard sensors. Auxiliary
freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and
without a four-minute delay in turnoff.
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder.
Message
Frequency
Action Required
rPH
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rSA
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rCL
Every 30 days
Remove, clean, and reinstall filter per manufacturer’s instructions.
rtg
Every 30 days
Test and reset GFCI per manufacturer’s instructions. Drain and refill
spa per manufacturer’s instructions.
rdr
Every 90 days
Drain and refill spa per manufacturer’s instructions.
rCO
Every 180 days
Clean and condition spa cover.
rCH
Every 365 days
Install a new filter.
Содержание Portable Spa
Страница 1: ...LTR20091000 Rev C 6 8 09...
Страница 11: ...2009 Portable Spa LTR20091000 Rev C Preparing for Your New Portable Spa www calspas com 9...
Страница 52: ...2009 Portable Spa LTR20091000 Rev C Appendix www calspas com 50 Cal Spas Chemicals...
Страница 53: ...2009 Portable Spa LTR20091000 Rev C www calspas com...
Страница 54: ...2009 Portable Spa LTR20091000 Rev C www calspas com...
Страница 55: ...2009 Portable Spa LTR20091000 Rev C www calspas com...