background image

2011 Genesis Portable Spa

LTR20111058, Rev. B

Pr

eparing f

or 

Your Ne

w P
or

tab
le Spa

www.calspas.com

5

All 230V spas must be permanently connected (hard-
wired)  to  the  power  supply.  These  instructions  de-
scribe the only acceptable electrical wiring procedure. 
Spas wired in any other way will void your warranty 

and may result in serious injury.

This  is  the  only  acceptable  electrical  wiring  proce-
dure. Spas wired in any other way will void your war-
ranty. See the wiring diagram on page 6.
The  electrical  wiring  of  this  spa  must  meet  the  re-
quirements of any applicable local, state, and federal 
codes. The electrical circuit must be installed by an 
electrical contractor and approved by a local building 
/ electrical inspector.

RCD and Wiring Requirements

Your spa will require either one 32 amp RCD or two 
16 amp RCDs, installed with three #10 AWG copper 
wires.
The power supplied to the spa must be on a dedi-
cated RCD protected circuit with no other appliances 
or lights sharing the power.

230V / 50 Hz

Use  copper  wire  with  THHN  insulation.  Do  not  use 

aluminum wire.
When wires larger than #6 AWG are required, install 

a junction box near the spa and use #6 AWG wire 

between the junction box and the spa.

Wire  runs  over  26  m  must  increase  wire  gauge  to 

the  next  lower  number.  For  example:  A  normal  50 

amp RCD with four #8 AWG copper wires run over 

26 m would require you to go to four #6 AWG cop-

per wires.

Testing the RCD Breaker

Test the RCD breaker prior to first use and periodical

-

ly when the spa is powered. To test the RCD breaker 

follow these instructions (spa should be operating):

Press the TEST button on the RCD. The RCD will 

1. 

trip and the spa will shut off.
Reset the RCD breaker by switching the breaker 

2. 

to the full OFF position, wait a moment, then turn 

the breaker back on. The spa should have power 

again.

Содержание LTR20111058

Страница 1: ...LTR20111058 Rev B 4 27 11...

Страница 2: ...justing Spa Water 15 Sanitation 16 Cleaning the Filter 18 Cleaning the Filter Basket 18 Bather Load 18 Starting the Spa with Fresh Water 19 Maintenance Schedule 20 Troubleshooting Water Clarity Proble...

Страница 3: ...r or water can induce hyperthermia Hyperthermia occurs when the inter nal temperature of the body reaches a level 3 F to 6 F above the normal body temperature of 98 6 F or 2 C to 4 C above 37 C While...

Страница 4: ...seases should not use a spa or hot tub WARNING To avoid injury exercise care when entering or exiting the spa or hot tub WARNING Do not use drugs or alcohol before or during the use of a spa or hot tu...

Страница 5: ...hen you plan the location of your spa Provide a View with Your Spa Think about the direction you will be facing when sitting in your spa Do you have a special landscaped area in your yard that you fin...

Страница 6: ...ing an extension cord will void your warranty Do not bury the power cord If your cord becomes damaged replace it before next usage If you need to replace your cord replace it with a 15 amp GFCI connec...

Страница 7: ...amp RCDs installed with three 10 AWG copper wires The power supplied to the spa must be on a dedi cated RCD protected circuit with no other appliances or lights sharing the power 230V 50 Hz Use coppe...

Страница 8: ...2011 Genesis Portable Spa LTR20111058 Rev B Preparing for Your New Portable Spa www calspas com 6 GREEN YELLOW Ground GREEN YELLOW Ground GREEN YELLOW Ground CIRCUIT BOARD RCD Wiring Diagram...

Страница 9: ...2011 Genesis Portable Spa LTR20111058 Rev B Preparing for Your New Portable Spa www calspas com 7 Circuit Board Connection...

Страница 10: ...be an air pocket at the suction side of the pump Shut off power to the spa and loosen the pump union on the suction side of the pump to bleed the air When air is bled turn power back on Install the pr...

Страница 11: ...ss the Up or Down button the set temperature will change up or down one degree Standard Economy and Sleep Heating Modes Your new spa is equipped with a heating feature that gives you complete control...

Страница 12: ...ary These features will automatically turn themselves off during periods of continuous use Low speed pump After 2 hours High speed pumps After 15 minutes Spa light After 4 hours Setting Filtration Cyc...

Страница 13: ...llow directions for dr message and press any button to reset spa Spa will not automatically reset when dry or dY is displayed Ec Indicates heater is in Economy Mode None Temperature unknown After the...

Страница 14: ...en your spa is first actuated it will go into priming mode The priming mode will last for up to four minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode...

Страница 15: ...the topside control pan el to turn the spa light on If your spa has LED lights they will also light up at the same time as the spa light The LED lights operate in three three modes Cycle 1 The first...

Страница 16: ...uamconum nis eu feugiamet vent et wisis ero dolore dip exeraestie estie vel inisci elisl ut diat cons aut alit lut lore tin hent adiam iustrud molor sustis essit wis cilit wisi Chemical Balance Ing et...

Страница 17: ...al alkalinity is 80 120 ppm If the TA is too low the pH level will fluctuate wide ly from high to low Low TA can be corrected by adding Cal Spas pH Alkalinity Up If the TA is too high the pH level wil...

Страница 18: ...o dissolve too quickly It will cause damage to your spa and will void your warranty Sanitizers kill bacteria and other organic waste by breaking them down to non harmful levels and are filtered out Ma...

Страница 19: ...r Spa must be running with all of the jets on high for 30 minutes with the cover open If necessary repeat oxidizer shock in 30 minute intervals Chemical Safety Do not exceed chemical dosages as recomm...

Страница 20: ...ing off the filter weekly to remove surface debris your filter should be deep cleaned pe riodically to dissolve scale and particles that get lodged deep within the filter fibers and impede the filtrat...

Страница 21: ...Purpose Cleaner Apply a protective coat of Cal Spas Fast Sheen 2 to the acrylic surface Fill the spa to the proper water level with normal 3 tap water Do not use soft water Use test strip and balance...

Страница 22: ...ter Follow filter cleaning instruction at beginning of Clear Water Plan Every two to four months Drain and clean your spa with Multi Purpose Cleaner Polish the acrylic surface with Fast Sheen Clean an...

Страница 23: ...nd refill the spa Organic buildup scum ring around spa Buildup of oils and dirt Wipe off scum with clean rag if severe drain the spa use a spa surface and tile cleaner to remove the scum and refill th...

Страница 24: ...k up the female end of a garden hose to the drain fit 5 ting Place the other end of the garden hose where you would like 6 the water to drain to Twist the hose bib fixture counterclockwise to open the...

Страница 25: ...drain plugs from the front of the 4 pumps Disconnect the unions from both sides of the 5 pump Use a wet dry vacuum to blow any remaining 6 water out of the jets and equipment area Cover your spa with...

Страница 26: ...eaning and Replacing the Filter Filtration is one of the most important steps you can take to ensure clean clear water It is far less expensive to fix water clarity problems by filtering your spa than...

Страница 27: ...a clean soft cloth 2 Wipe spa thoroughly with a wet sponge rinsing 3 often in a bucket of clean water Cal Spas Multi Purpose Cleaner should not be sprayed directly into the spa water Incorrect usage o...

Страница 28: ...Mini 2 Diameter LIT16000151 Covers G418T 72 x 72 Basic Rust 4 2 5 ACC01200616 Basic Gray 4 2 5 ACC01200617 Basic Slate 4 2 5 ACC01200618 Basic Palomino 4 2 5 ACC01200619 G318R 78 Round Basic Rust 4 2...

Страница 29: ...defects in ma terials and or workmanship for one year Manufacturer Warranty Spa cover warranty is extended through the manufacturer of the product Spa cover is warranted for 90 days unless otherwise s...

Страница 30: ...ither a known or an unknown problem Damage caused by tri chlor acids chlorine tab lets any floating chemical devices or any spa chemicals not authorized by LMS Damage caused by improper water chemistr...

Страница 31: ...2011 Genesis Portable Spa LTR20111058 Rev B Appendix www calspas com 29 Cal Spas Chemicals...

Страница 32: ..._________________ Date Purchased _ _____________________________________________ Date Installed ________________________________________________ Dealer s Phone Number _________________________________...

Отзывы: