background image

Inground Spas

LTR20111002, Rev. A

Pr

eparing f

or 

Your Ne

w Ingr

ound Spa

www.calspas.com

9

IG-404

Содержание LTR20111002

Страница 1: ...LTR20111002 Rev A 1 24 11...

Страница 2: ...ue to continuous improvement programs all models operation and or specifications are subject to change without prior notice LTR20111002 Rev A 1 24 11 100 923 CONTACT INFORMATION For customer service p...

Страница 3: ...y to lights built in to the spa as factory options from Cal Spas WARNING RISK OF INJURY The spa water should never exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered...

Страница 4: ...y rec reation be sure to leave plenty of room around it for activity If you will use it for relaxation and therapy you ll probably want to create a specific mood around it Plan for Your Environment If...

Страница 5: ...ecause it will require the least amount of prep aration for the dig but in many cases there is no level area therefore the site must be prepared to accept the spa prior to dig The spa site should be e...

Страница 6: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 6 Spa Shell Dimensions and Side Views IG 401...

Страница 7: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 7 IG 402...

Страница 8: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 8 IG 403...

Страница 9: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 9 IG 404...

Страница 10: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 10 IG 405...

Страница 11: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 11 IG 406...

Страница 12: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 12 IG 407...

Страница 13: ...GFCI and wir ing requirements Spa Model GFCI Required Wires Required Designer inground spas with one 5 5 kW heater One 50 amp GFCI Four 6 AWG copper wires Designer inground spa with two 5 5 kW heaters...

Страница 14: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 14 GFCI Wiring Diagram...

Страница 15: ...use aluminum wire Use the table below to determine your GFCI and wir ing requirements Wire runs over 85 feet must increase wire gauge to the next lower number For example A normal 50 amp RCD with fou...

Страница 16: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 16 RCD Wiring Diagram GREEN YELLOW Ground GREEN YELLOW Ground GREEN YELLOW Ground CIRCUIT BOARD...

Страница 17: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 17 Installing the Inground Shell...

Страница 18: ...testing at the factory This is done to assist in stallers in properly identifying the installation We still recommend that the installers verify plumbing lines prior to gluing This can be done by usin...

Страница 19: ...of 90 elbows as much as possible The use of 45 elbows will increase the amount of jet pres sure you will have over the use of 90 elbows The plumbing on the spa shell is labeled by the factory in the f...

Страница 20: ...ength Take this into consideration when verifying electrical and plumbing runs Electrical and Electronic Connection Connect the extension loom to the control panel 5 location on the circuit board loca...

Страница 21: ...volt models to a low voltage transformer no further than 25 7 6m Remember this is a water cooled light so the con duit and all connections must be leakproof Feed the light cord through the rigid condu...

Страница 22: ...Inground Spas LTR20111002 Rev A Preparing for Your New Inground Spa www calspas com 22...

Страница 23: ...deck up to the spas coping then the top of the coping should be 4 above the surrounding area In either event it is recommended to dig out an area around the spa exposing the flange of the coping and...

Страница 24: ...es Press MODE PROG to enter mode program 1 ming Press the DOWN button to cycle through to the 2 desired mode Press MODE PROG to confirm selection 3 Standard Mode This is programmed to maintain the des...

Страница 25: ...ycle is automatically activated at 8 00 AM and operates the pump until 10 00 AM The FILTER 1 indicator icon will light when filter 1 is running The second filter cycle is automatically activated at 8...

Страница 26: ...10 F below the desired usage temperature and reheating it prior to usage will cause the heater to operate longer than it normally would maintaining the desired tem perature Doing this will increase y...

Страница 27: ...third occurrence of dr message Follow directions for dr message and press any button to reset spa Spa will not automatically reset when dry or dY is displayed Ec Indicates heater is in Economy Mode No...

Страница 28: ...ture in the Standard mode SF Safety Suction Spa is shut down The display will show SF when a vacuum switch closes All functions will turn off and the system will be disabled until a panel button is pr...

Страница 29: ...e jet Neck jets adjust in the opposite directions counter clockwise to increase clockwise to decrease Diverter Knobs Diverter knobs are 1 and 2 knobs located around the top of your spa They allow you...

Страница 30: ...rci te ea consequat Met prate er sit dolor iriureetuer si Feummy nullamcore magna ad dio er sequamconum nis eu feugiamet vent et wisis ero dolore dip exeraestie estie vel inisci elisl ut diat cons aut...

Страница 31: ...alinity is 80 120 ppm If the TA is too low the pH level will fluctuate wide ly from high to low Low TA can be corrected by adding Cal Spas pH Alkalinity Up If the TA is too high the pH level will tend...

Страница 32: ...t to dissolve too quickly It will cause damage to your spa and will void your warranty Sanitizers kill bacteria and other organic waste by breaking them down to non harmful levels and are filtered out...

Страница 33: ...ning with all of the jets on high for 30 minutes with the cover open If necessary repeat oxidizer shock in 30 minute intervals Chemical Safety Do not exceed chemical dosages as recommended in the Clea...

Страница 34: ...nce and heating efficiency In addition to spraying off the filter weekly to remove surface debris your filter should be deep cleaned pe riodically to dissolve scale and particles that get lodged deep...

Страница 35: ...ply a protective coat of Cal Spas Fast Sheen 2 to the acrylic surface Fill the spa to the proper water level with normal 3 tap water Do not use soft water Use test strip and balance the spa water 4 Ad...

Страница 36: ...instruction at beginning of Clear Water Plan Every two to four months Drain and clean your spa with Multi Purpose Cleaner Polish the acrylic surface with Fast Sheen Clean and treat spa cover pillows a...

Страница 37: ...ill the spa Organic buildup scum ring around spa Buildup of oils and dirt Wipe off scum with clean rag if severe drain the spa use a spa surface and tile cleaner to remove the scum and refill the spa...

Страница 38: ...ance Important Keep the spa covered when not in use Covered spas will use less electricity in maintain ing your set temperature Covering your spa will protect your spa s finish from the sun s ultravio...

Страница 39: ...formation on cleaning your filter Winterizing Cold Climate Draining In many areas of the country the temperature drops below 32 F 0 C We recommend that you always have your spa full of water and runni...

Страница 40: ...Cleaner Spa finish cleaning Cal Spas All Purpose Cleaner is an essential part of maintaining your spa s finish Through normal use the spa s finish can accumulate dirt oil and calcium causing a rough f...

Страница 41: ...d the spa s finish will actually start to resist most of the elements that cause calcium build up and make scum line clean up easier Prior to Spa Start Up and Refilling Spray Cal Spas Multi Purpose Cl...

Страница 42: ...umbo Spa Light LIT16100156 Covers Deluxe Rust Deluxe Gray Deluxe Slate Deluxe Palomino Deluxe Teal Deluxe Navy Deluxe Hunter DIJ 401 93 Round ACU02200310 ACU02200311 ACU02200315 ACU02200316 ACU0220031...

Страница 43: ...Inground Spas LTR20111002 Rev A Appendix www calspas com 43 Cal Spas Chemicals...

Страница 44: ...LTR20111002 Rev A 1 24 11 LMS Customer Service Department 1462 East Ninth Street Pomona CA 91766 Toll Free 1 800 CAL SPAS Fax 1 909 629 3890 www calspas com...

Отзывы: