2008 Portable Spa Owner’s Manual
Page 13
LTR20081000, Rev. E
Operating Your Spa
HL
A difference in readings between temperature sensors has been detected indicating a possible
water flow problem. Make sure spa is filled to proper level and that pumps are primed (water
is flowing). Also check to make sure filter cartridges are clean. If message does not reset, call
your dealer or service organization.
LF
This will display on the 5th occurrence of the
HL
message in 24 hours indicating a persistent flow
problem. The heater will be shut down but other functions will continue to operate. Follow
HL
message actions then press any button to reset.
dr
Insufficient water flow through the heater has been detected. Spa will be shut down for 15
minutes. Check water level and fill spa if water level is low. Make sure pumps are primed (water
is flowing) and filter cartridges are clean. Press any button to reset or wait 15 minutes and spa
will automatically reset. If message does not reset, call your dealer or service organization.
dY
Insufficient water level detected in heater. This will display on the 3rd occurrence of
dr
message.
Follow directions for
dr
message and press any button to reset spa. Spa will not automatically
reset when
dY
is displayed.
Sf
Safety Suction System (spa is shut down). The display will show
Sf
as soon as the vacuum
switch closes. All functions will turn off and the system will be disabled until a panel button is
pressed.
ST
Indicates heater is in standard mode.
Ec
Indicates heater is in economy mode.
SL
Indicates heater is in sleep mode.