background image

Users Manual

CAL Controls

Temperature Controllers

CAL 3300 / 9300 / 9400

Autotune Temperature

Controllers

English

Français

Deutsch

Italiano

Español

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание CAL 3300

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...ature Controllers CAL 3300 9300 9400 Autotune Temperature Controllers E n g l i s h F r a n a i s D e u t s c h I t a l i a n o E s p a o l Artisan Technology Group Quality Instrumentation Guaranteed...

Страница 3: ...xit program mode Press together for 3 seconds To scroll through functions Press or To change levels or options Press together or together To view setpoint Press To increase setpoint Press together To...

Страница 4: ...SP2 mode nonE LtCH hold Lt ho nLin Display resolution 1 or 0 1 degree Set scale maxim um 0 0 Sensor max to sensor full scale Set scale minim um 0 0 Sensor min to sensor full scale Select input sensor...

Страница 5: ...n 100 C Re tuning after a large setpoint change Tuning multi zone and or heat cool applications Notes DAC is not re adjusted by Tune at setpoint Proportional Cycle Time can be pre selected before runn...

Страница 6: ...OTUNE is initiated select CYC t in Level 1 press and hold both and or buttons until indexing stops at preferred value then exit program to accept CYCLE TIME RECOMMENDATIONS PROGRAMMER RAMP SOAK This f...

Страница 7: ...lternating with the process temperature during alarm condition Notes The alarm will be automatically reset when the temperature returns within the bnd 2 setting in Level 1 The annunciator may be disab...

Страница 8: ...OFF mode oFSt 0 to C F SP1 offset manual reset 50 bAnd Applicable in proportional and ON OFF mode with integral disable Int t oFF SP LK oFF on Lock main setpoint Locks the setpoint preventing unauthor...

Страница 9: ...vice read only burn Sensor burn out break protection Caution Settings affect fail safe state SP1 SP2 uP SC Upscale Upscale dn SC Downscale Downscale 1u 2d Upscale Downscale 1d 2u Downscale Upscale rEu...

Страница 10: ...T 1 16 DIN 45 0mm 0 6 0 0 wide 45 0mm 0 6 0 0 high 1 32 DIN 45 0mm 0 6 0 wide 22 2mm 0 3 0 high Maximum panel thickness 9 5mm Minimum spacing 20mm vertical 10mm horizontal MOUNTING To mount a Controll...

Страница 11: ...cifications EN61010 CSA 22 2 No 1010 1 92 Compliance shall not be impaired when fitted to the final installation Designed to offer a minimum of Basic Insulation only The body responsible for the insta...

Страница 12: ...to 50mV Applicable to all inputs SM sensor maximum Calibration accuracy 0 25 SM 1 C Sampling frequency input 10Hz CJC 2 sec Common mode rejection Negligible effect up to 140dB 240V 50 60Hz Series mod...

Страница 13: ...and materials for three 3 years from date of purchase 1 Should the unit malfunction return it to the factory If defective it will be repaired or replaced at no charge 2 There are no user servisable p...

Страница 14: ...0 1462 436161 Fax 44 0 1462 451801 email support cal controls co uk http www cal controls com CAL Controls Inc 1580 S Milwaukee Avenue Libertyville IL 60048 USA Tel 847 680 7080 Fax 847 816 6852 33017...

Страница 15: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...