15
Y2
OFF
0
10 V
INPUT
(V DC)
M1
1
10
Y1
1,1
MAX rpm
ON
0,9
MIN rpm
CARATTERISTICA DELLE USCITE /
OUTPUT FEATURE
7.4
7.5
make the electrical connections to a thermostat fit for use
according to the diagram
The 10V input, if the S1 input which the grill safety micro
switch is connected to is closed, activates solenoid valve Y1
and regulations fan revolutions.
The speed "ramp" provides for linear regulation from the
minimum value (400 rpm) to the maximum value (1,400 rpm)
for voltage values ≥ 1.1V÷10 V DC.
The motor is off when values are lower than 1V DC.
The Y1 solenoid valve is activated for power values > 1V
DC and switches off then the power drops below 0.9V
DC.
Connection diagram MB 010 E with 0-10V DC thermostats / signals
MB 010 E connections with 0-10V thermostats
L-N
Electrical power supply 230V-50 Hz
10V
Appliance piloting input 0÷10 V
Y1
water solenoid valve (230V/ 50Hz 1A output
voltage)
Y2
output for mobile suction panel servo (power
output 230 V/ 50Hz 1A)
RS
RS version cabling
HRS
water probe for RS 2 kΩ
M1
DC inverter fan motor
S1
safety micro-switch for grill
Input impedance 25 kΩ /
Input impedance 25 kΩ /
EN