FICHE D’INSTRUCTION
TECHNIQUE
N° : V 54 1006
PINCE PNEUMATIQUE CLIC COMPACTE
CLIC PNEUMATIC PLIERS
CLIC DRUCKLUFTZANGE
PINZA PNEUMATICA CLIC
PINZA NEUMATICA CLIC
Date : 07/11/2017
Indice : C
Page 14/16
4.
PROBLEM RESOLUTION
Problem
Causes
Solution
1
The jaws do not close.
Lack of compressed air.
Defective trigger or valve
block.
Check compressed air supply
connection as well as trigger and
control valve integrity.
Replace them if necessary
2
Compressed air leaks around the
hose connection.
Hose not properly fitted in
connector.
Check hose connection.
3
Compressed air leaks around the
control valve.
Control valve or O-rings
worn out.
Replace the O-rings or the valve kit.
4
Loss of power
Improper air supply or leaks
Check that pressure complies with
instruction manual and search for
leaks.
5
Clamp not clipped
Wrong head
Check if the head PN is adapted to the
clamp to clip.
Worn out jaws
Check the jaw’s closing dimension
Loose nut
Check if the
head’s fastening nut is
properly tightened.
Worn out or broken axes
Check for clearance in the axes
6
The jaws do not return to initial
position
Damaged or broken springs
Replace the springs
Chips/debris creating
mechanical blocking
Clean with compressed air (blower)