5.1
Connecting power and water
Preparation
The following is not supplied by Cafi na, and must be
provided by you for installation:
CAUTION
On the installation side, an all-pole separator
with minimum contact-opening of 3 mm per
pole must be provided.
• Maximum system impedance 0.10 ohms at
mains connection of building. (You can enquire a
bout impedance from your power supplier.)
• Plug and socket for power connection
• External main switch for power connection
• Pipes and main tap for water connection
•
Maximum pressure of water supply 0.5 MPa
(5 bar)
•
Maximum fl ow temperature of water: 20° C
Please ensure that these preparations have
been made or that this equipment is to hand by
the day when installation is to take place.
DANGER: Risk of fatality
from electric shock!
• If sockets are used with the incorrect voltage,
electric shock will result, along with irreparable
damage to the Cafina A
LPHA
.
➤
In the event of power or water being discon-
nected, use the connections allocated by the
service engineer. If in doubt, always contact
authorized experts.
WARNING
A damaged appliance is unsafe and can cause
serious injury and fi re.
➤
Protect appliance from weather such as rain,
frost and direct sunlight, to prevent damage
along with potential injury and fi re.
➤
Do not immerse appliance or parts of appliance
such as cables and connections in water.
CAUTION
Observe national regulations when connecting
to the water supply.