Screws, wall 

fasteners, washers

Duct Transition 

with Damper

761Dia65

Filter 

Support

INST

ALLA

TION PREP

ARA
TION

PARTS PROVIDED

Locate the hardware accessory box packed with the hood and check contents.

DUCT COVER REQUIREMENTS

We recommend that the vent hood and decorative 

duct cover (if used) be on site before final framing 

and wall finishing. This will help to accurately locate 

studs, ductwork, and electrical service. Read these 

instructions to determine if the duct cover accessory 

can be used for your installation situation.

Duct Cover Accessory:

•  Use the decorative duct 

cover to conceal ductwork 

running from the top of the 

hood to the ceiling. 

•  The duct cover accessory 

consists of 2 pieces. The 

outside piece is 12” high, 

the inside piece is 22”. 

Nested together they are 

24” minimum expanding to a 

total maximum height of 34”.

•  The outside piece can be 

used alone to fill a 12” height.

•   For heights over 12”, the ceiling bracket must be 

installed to secure the cover at the top.

To avoid unsightly gaps, plan the hood installation 

height for duct cover use.

•  The cover will fit a 12” minimum height from the top of 

the hood to the ceiling or 24” minimum and expanding 

up to 34” from the top of the hood to the ceiling.

THE DUCT COVER CANNOT BE USED WHEN THE 

DISTANCE ABOVE THE TOP OF THE HOOD IS 

BETWEEN 12” AND 24”.

Review the following examples to ensure a trouble free 

installation using the duct cover accessory.

8ft. Ceilings: 

The hood 

must be installed at 

30” above the cooking 

surface (or 66” above 

the floor). the duct cover 

will not fit if the hood 

is installed at a lower 

or higher height. Use 

the outside 12” section, 

discard the inside section.

9 ft Ceiling:

 Install the hood 24” min. and up to a 

maximum of 30” above the cooking surface. The duct 

cover will expand to reach ceiling height.

10 ft. Ceiling:

 Install the hood 32” min to 36” max. 

above the cooking surface. The duct cover will expand 

to a maximum of 34” above the top of the hood to 

meet the ceiling.

Installation Preparation

2 Aluminum 

Grease Filters

22”

11”

12”

12”

12”

24”

9 ft. Ceiling

30”

24”

30”

30”

10 ft. Ceiling

36” Max

32”

34”

12”

8 ft. Ceiling

30”

Содержание CVW9301

Страница 1: ...ds Models CVW9301 and CVW9361 Contents Safety Information 3 Using the Hood Controls 5 Care And Cleaning Filter 6 Surfaces 6 Lights 7 Installation Instructions 8 Troubleshooting Tips 20 Limited Warrant...

Страница 2: ...ll too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your CAF appliance now online Helpfu...

Страница 3: ...ERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the fl...

Страница 4: ...all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prev...

Страница 5: ...reduces cooking odors and soiling moisture that create a frequent need for cleaning NOTE When the fan is operating on the LO setting it will be very quiet Always make sure that the fan is turned OFF...

Страница 6: ...e use warm sudsy water or a stainless steel cleaner or polish Always wipe the surface in the direction of the brush line Follow the cleaner instructions for cleaning the stainless steel surface Cleane...

Страница 7: ...e socket 2 Using gloves or a dry cloth remove the bulb by pulling it straight out To replace 1 Use a new 12 volt 20 watt maximum Halogen bulb for a G 4 base 2 Using gloves or a dry cloth remove the ne...

Страница 8: ...nel CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION WARNING Disconnect all ele...

Страница 9: ...these hoods 24 required minimum and 36 recommended maximum above the cooking space In this installation the ductwork running from the top of the hood will be concealed in the soffit or upper cabinetry...

Страница 10: ...rdance with local building code requirements Visit cafeappliances com for available makeup air solutions Wall Framing for Adequate Support This vent hood is heavy Adequate structural support must be p...

Страница 11: ...ation Preparation POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED Remove house fuse or open circuit breaker before beginning installat...

Страница 12: ...ece and screws for later installation Do not discard Remove the V shaped carton insert Remove parts package from the V shaped cardboard insert Remove junction box cover and knockout Install strain rel...

Страница 13: ...lled to secure the cover at the top To avoid unsightly gaps plan the hood installation height for duct cover use The cover will fit a 12 minimum height from the top of the hood to the ceiling or 24 mi...

Страница 14: ...ition For Ducting Through Rear Wall Measure the supplied duct transition with any straight run length of duct used plus 90 elbow height Draw a horizontal line on the wall intersecting the centerline H...

Страница 15: ...wood support The top keyhole slots in the hood should engage the protruding mounting screws Allow the hood to slide down into position Pull house wiring through knockout at the rear or top of the hoo...

Страница 16: ...e strongly recommend that the hood also be secured to the back wall with wall fasteners Drill four 1 8 pilot holes in locations show If mounting to the underside of a cabinet with a recessed bottom in...

Страница 17: ...ecure the bracket to the rear wall with wood screws and washers Use wall anchors if needed NOTE Bracket has 2 sets of holes Use larger holes for wall fasteners or wood screws with washers Use smaller...

Страница 18: ...the top of the hood with 4 screws provided See illustration page 16 Extend the inside section upwards to meet the ceiling and ceiling bracket Secure the duct cover to the bracket with the 2 small Phil...

Страница 19: ...the top of the vertical front panel Tap the filter against one side to align with outside opening Pull the filter down into the lower slots at the bottom of the filter support To remove the filters gr...

Страница 20: ...r plug is loose or you see the connector dangling the installer failed to plug it in securely Although it is a blind connection it is easy to plug in See the Installation Instructions in this manual f...

Страница 21: ...49 2000061 21 Notes...

Страница 22: ...ange Hood Limited Warranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties...

Страница 23: ...hine Stainless Steel Wipes CERAMA BRYTE Stainless Steel Appliance Cleaner Bar Keepers Friend Soft Cleanser Looking For Something More CAF offers a variety of accessories to improve your cooking and ma...

Страница 24: ...about special discounts that are available while your warranty is still in effect You can purchase it on line anytime CAF Service will still be there after your warranty expires In the US cafeapplian...

Отзывы: