Frequency Band 

902÷928 MHz (FCC part 15) 
865.600÷867.600 MHz (ETSI EN 302 208) 

RF Power 

Programmable in 15 levels (1dB step) from 12dBm ERP to 26dBm ERP (from 
16mW ERP to 400mW ERP) 

Antenna 

Integrated Circular Polarized Antenna 

Number of Channels 

4 channels (compliant to ETSI EN 302 208 v1.2.1) 
50 hopping channels (compliant to FCC part 15.247).  
All subsets of FCC band are supported 

Standard Compliance 

EPC C1G2/ISO 18000-6C 

User Interface 

Green LED: Power 
Blinking red LED: Tag detection 
Blinking yellow LED: USB communication activity 
Buzzer: user programmable event signaling 

USB Device Port 

USB Type A plug connector 
Bus powered USB 2.0 device 
Must be connected to Hight-power Port (500 mA @ VBUS) 
It appears as USB serial port 
Virtual  Com  Port  (VCP)  drivers  for  Windows  XP/Vista/Seven  (7),  Windows 
CE 4.2, Linux 2.40 and greater 
Baudrate: 115200 
Databits: 8 
Stopbits: 1 
Parity: none  
Flow control: none 

Dimensions 

(W)297 x (L)205 x (H)15 mm

3

  

(11.7 x 8 x 0.6 inch

3

Electrical Power 

5 V DC bus powered (USB) 
Max 400 mA 

Operating Temperature 

-10 °C to +55 °C 

Weight 

525 g 

Length of USB cable 

1,5 m 

Tab. 3.1: Slate R1260I Technical Specifications  

 

Reader – Tag Link Profiles 

Slate R1260I reader supports different modulation and return link profiles according to EPC Class1 Gen2 protocol. 

In the following table are reported all profiles that have been tested for the compliance with ETSI and FCC regulations. 

Link profile # 

Regulation 

Modulation 

Return Link 

ETSI - FCC 

DSB–ASK; f=40kHz 

FM0; f = 40kHz 

ETSI - FCC 

DSB–ASK; f=40kHz 

Miller (M=4); f = 256kHz 

Tab. 3.2: Slate R1260I Reader to tag link profiles 

 

Содержание Easy2Read Slate R1260I

Страница 1: ...R1260I RFID UHF Desktop Reader Technical Information Manual Revision n 00 09 02 2011...

Страница 2: ...his device generates uses and can radiate radio frequency energy If not installed and used in accordance with the instruction manual the product may cause harmful interference to radio communications...

Страница 3: ...Disposal of the product Do not dispose the product in municipal or household waste Please check your local regulations for disposal recycle of electronic products...

Страница 4: ...Technical Specifications Table 17 Reader Tag Link Profiles 17 Radiation Patterns 18 4 SLATE R1260I Regulatory Compliance 19 FCC Compliance 20 CE Compliance 20 RoHS EU Directive 20 DECLARATION OF CONF...

Страница 5: ...echnical Information Manual 1 Introduction This Chapter gives general information about the SLATE R1260I UHF Desktop Reader It contains these topics General Information Ordering Code Accessories Insta...

Страница 6: ...lock for smart shelves and smart displays Being compliant with both European and US regulatory environments the Slate reader allows installations in various countries worldwide as needed by retailers...

Страница 7: ...ssories below No 2 wall hooks No 4 rubber feet No 2 rawlplugs 4 mm screws No 2 small screws 3 mm Installation Notice The Slate R1260I can be easily placed on a table for desktop applications or it is...

Страница 8: ...Installation The Slate can be hanged on the wall see Fig 1 3 Slate R1260I Wall mounting First of all use the two small screws 3 mm to fix the 2 hooks on the Slate Then to hang the Slate on the wall f...

Страница 9: ...ual 2 SLATE R1260I Functional Description This Chapter gives a functional description of the SLATE R1260I UHF Desktop Reader It contains these topics Main Features External Connection Front Panel Leds...

Страница 10: ...60I is powered through the USB host Front Panel Leds The Slate R1260I front panel houses the following Leds see Fig 1 2 Slate R1260I Technical drawings top view LEDS FUNCTION TYPE POWER Power ON Green...

Страница 11: ...ation Manual 3 Insert the CD provided together with the SLATE R1260I Select No not this time and click on next 4 Select Install from a list or specific location and click on next 5 Select Search remov...

Страница 12: ...Information Manual 6 When the installation is successfully terminated press on Finish 7 Now the driver installation procedure is completed Open the System properties right click on My computer icon H...

Страница 13: ...SB serial port COM X in the case below COM4 9 Once the serial port connection is established CAEN RFID Show software can be used to interface the reader Open CAEN RFID Show Click on File Connect Type...

Страница 14: ...Slate R1260I Technical Information Manual 10 Now the Slate R1260I is ready to perform tag scanning and read write operations...

Страница 15: ...grade the firmware follow the steps below Verify the virtual COM port associated to the reader Open the FW upgrade program Select the COM port Select the image file by clicking on Open button Click on...

Страница 16: ...nual 3 SLATE R1260I Technical Specifications This Chapter introduces the technical specifications of the SLATE R1260I UHF Desktop Reader It contains these topics Technical Specifications Table Reader...

Страница 17: ...t be connected to Hight power Port 500 mA VBUS It appears as USB serial port Virtual Com Port VCP drivers for Windows XP Vista Seven 7 Windows CE 4 2 Linux 2 40 and greater Baudrate 115200 Databits 8...

Страница 18: ...echnical Information Manual Radiation Patterns The radiation patterns of Slate R1260I are shown in the following figures Fig 3 1 Slate R1260I Radiation pattern H plane Fig 3 2 Slate R1260I Radiation p...

Страница 19: ...Slate R1260I Technical Information Manual 4 SLATE R1260I Regulatory Compliance...

Страница 20: ...se of other than the approved antenna with this unit may result in harmful interference with other users and cause the unit to fail to meet regulatory requirements CE Compliance Reference standard CEI...

Страница 21: ...SI EN 301 489 1 V 1 8 1 2008 ETSI EN 301 489 3 V 1 4 1 2002 ETSI EN 302 208 2 V 1 2 1 2008 CEI EN 50364 2002 CEI EN 50357 2002 The present document declares that the specified product complies with th...

Отзывы: