easy2log© RT0005 Technical Information Manual
22
Register description
CONTROL register (RW)
Register
Address
Op.
Default
CONTROL
0x0A
RW
0x0010
The register is composed by the following fields:
15..12
11
10..8
7
6
5
4
3
2
1
0
RFU
SD RFU
ARRE MKTE RFSL_MBIT RFSL_LBIT DE LE BE RST
RST (RW) - Reset bit
: Reset bit is used to erase all the log memory and reset all the memory pointers and counters
included the histogram bins. The value of the bit remain set until the reset operation is performed then it returns to 0.
Default value is 0.
BE (RW) - Button_Enable bit
: if the Button_Enable bit is set the RT0005 button can be used to start and to stop the
logging activity. Default value is 0.
LE (RW) - Logging_Enable bit
: Logging_Enable bit is used to enable(1)/disable(0) the logging activity. If the
Button_Enable bit is set the Logging_Enable bit can be set/reset using the manual interface. Once stopped, the logging
activity can be restarted only after the tag has been reset using the RST bit. Default value is 0.
DE (RW) - Delay_Enable bit
: Delay_Enable bit is used to enable(1)/disable(0) the usage of the SAMPLING_DELAY
register. If enabled, the first sample's acquisition is done SAMPLING_DELAY second after the start of the logging
activity. Default value is 0.
RFSL (RW) - RF_Sensitivity_Level
: RF_Sensitivity_Level register is used to set the sensitivity level of the radio frequency
front-end. Sensitivity can be set on 3 different levels: 3 = maximum sensitivity level, 1 = minimum sensitivity level.
Default value is 1.
MKTE (RW) - Mean_Kinetic_Enable bit
: Mean_Kinetic_Enable bit is used to enable(1)/disable(0) the Mean Kinetic
Temperature calculation. Default value is 0.
ARRE (RW) - Arrhenius_Enable bit
: Arrhenius_Enable bit is used to enable(1)/disable(0) the calculation of the
remaining Shelf Life (SHL_TIME) of the product using the Arrhenius equation with linear approximation. Default value is
0.
SD (RW) - Stop_Disable bit
: if the Stop_Disable bit is set the RT0005 button cannot be used to stop the logging activity.
Default value is 0.
SAMPLING_DELAY register (RW)
Register
Address
Op.
Default
SAMPLING_DELAY
0x0B
RW
0x0E10
Sampling_Delay register defines the delay, in seconds, of the first acquisition after the start of the logging activity.
Register value range is 0 to 65535; default value is 3600 (seconds) corresponding to 1 hour delay. The sampling delay is
activated if the corresponding bit on the CONTROL register (DE) is enabled.