Caen ELS FMC-4SFP+ Скачать руководство пользователя страница 6

 

FMC-4SFP+ - User’s Manual 

 

Safety information - Warnings 

 
 
 

CAEN ELS will repair or replace any product within the guarantee period if the 

Guarantor declares that the product is defective due to workmanship or materials and 
has not been caused by mishandling, negligence on behalf of the User, accident or any 
abnormal conditions or operations. 
 

Please read carefully the manual before operating any part of the instrument 

 

 

WARNING

 

 

Do NOT open the boxes 

 
 
 

 

CAEN ELS s.r.l. declines all responsibility for damages or injuries caused 

by an improper use of the Modules due to negligence on behalf of the User. It is 
strongly recommended to read thoroughly this User's Manual before any kind of 
operation.  
 
 

CAEN ELS s.r.l. reserves the right to change partially or entirely the contents of this 

Manual at any time and without giving any notice. 

 
 

Disposal of the Product 

 

The product must never be dumped in the Municipal Waste. Please check your local 

regulations for disposal of electronics products. 

 

 

 
 
 

Содержание FMC-4SFP+

Страница 1: ...FMC 4SFP Dual and Quad channel SFP SFP FMC Adapter Pin Assignments All Rights Reserved CAEN ELS s r l Rev 1 2 October 2017 FMC FPGA MEZZANINE CARD...

Страница 2: ...FMC 4SFP User s Manual 2...

Страница 3: ...FMC 4SFP User s Manual 3 For technical assistance please refer to the following contact...

Страница 4: ...MC SFP OVERVIEW 9 1 2 FMC CONNECTIONS 10 1 2 1 ROW A 10 1 2 1 ROW B 11 1 2 1 ROW C 11 1 2 1 ROW D 12 1 2 1 ROW E 13 1 2 1 ROW F 13 1 2 1 ROW G 13 1 2 1 ROW H 15 1 2 1 ROW J 16 1 2 1 ROW K 16 2 CLOCK G...

Страница 5: ...FMC 4SFP User s Manual 5 Document Revisions Document Revision Date Comment 1 0 November 5th 2015 First Release 1 1 April 1st 2016 Corrected VADJ range 1 2 October 27th 2017 Format changed...

Страница 6: ...ny part of the instrument WARNING Do NOT open the boxes CAEN ELS s r l declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the U...

Страница 7: ...d Before you use the device inspect the instrument for possible cracks or breaks before each use Do not operate the device around explosives gas vapor or dust Always use the device with the cables pro...

Страница 8: ...environmental requirements for a correct operation of the instrument Environmental Conditions Requirements Operating Temperature 0 C to 50 C Operating Humidity 30 to 85 RH non condensing Storage Tempe...

Страница 9: ...to the FMC standard ANSI VITA 57 1 All module pins are translated to the FMC carrier voltage VADJ that can be in the range from 1 5V to 3 3V With its low operation voltage it can be used on almost all...

Страница 10: ...FF 8418 FMC output A11 DP3_M2C_N Module 1 RX outer module module dependent SFF 8418 FMC output A14 DP3_M2C_P Not Connected A15 DP3_M2C_N Not Connected A18 DP3_M2C_P Not Connected A19 DP3_M2C_N Not Con...

Страница 11: ...RX inner module module dependent SFF 8418 FMC output C10 LA06_P MODABS Module 4 LVCMOS VADJ FMC output C11 LA06_N MODABS Module 3 LVCMOS VADJ FMC output C14 LA10_P RS0 Module 4 LVCMOS VADJ FMC input C...

Страница 12: ...VADJ FMC output D14 LA09_P TXDISABLE Module 2 LVCMOS VADJ FMC input D15 LA09_N TXDISABLE Module 1 LVCMOS VADJ FMC input D17 LA13_P RS1 Module 2 LVCMOS VADJ FMC input D18 LA13_N RS1 Module 1 LVCMOS VAD...

Страница 13: ...r Supply Not used in LPC carriers Table 4 FMC Row E connection 1 2 1 ROW F All FMC ROW F GND pins are connected to ground and the other pins are left unconnected except the PIN F40 see the following t...

Страница 14: ...d LVCMOS VADJ Do not use G21 LA20_P Not Connected G22 LA20_N Not Connected G24 LA22_P I2C SCL Module 2 LVCMOS VADJ open drain I2C G25 LA22_N I2C SDA Module 2 LVCMOS VADJ open drain I2C G27 LA25_P Si57...

Страница 15: ...OS VADJ FMC output H14 LA07_N MODABS Module 1 LVCMOS VADJ FMC output H16 LA11_P RS0 Module 2 LVCMOS VADJ FMC input H17 LA11_N RS0 Module 1 LVCMOS VADJ FMC input H19 LA15_P Reserved LVCMOS VADJ Do not...

Страница 16: ...Pins Power Supply Table 7 FMC Row H connections available only in 4 channel version 1 2 1 ROW J All FMC ROW J GND pins are connected to ground and the other pins are left unconnected 1 2 1 ROW K All...

Страница 17: ...15 MHz 1 1 0 250 00 MHz 1 1 1 Do not use Table 8 Start up Clock Frequency The Silicon Labs clock generation chip is accessible also using the I2C bus so it is possible to communicate directly with the...

Страница 18: ...ilable in two main different versions differing by the number of SFP channels F M C 4 S F P X X A A A 4 FMC 4SFP Quad channel SFP SPF FMC Adapter 2 FMC 2SFP Dual channel SFP SPF FMC Adapter NOTE field...

Страница 19: ...7 1 FMC Connector Type LPC HPC compliant Number of SFP Channels 2 on FMC 2SFP 4 on FMC 4SFP VADJ Range 1 5 V 3 3 V On board Oscillator Range 10 MHz 280 MHz On board Oscillator Configuration Protocol I...