FAST-Bi-1K5 – User’s Manual
23
More details on the output connector are reported in section 3.5.1
FAST-Bi-1K5 HV models (with nominal output voltage > 50 V)
FAST-Bi-1K5 models that have output voltage > 50 V shall be connected to the load
with a double insulation cable which have voltage rating adequate to the maximum
output voltage.
More details on the output connector are reported in section 3.5.2.
Hazardous voltage exists at the outputs and the load
connections. To protect personnel against accidental contact
with hazardous voltage, ensure that the load and its
connections have no accessible live parts. Ensure that the
load wiring insulation ratings is greater than or equal to the
maximum output voltage of the PS.
2.6
Recommended Length for Cables
The recommended length for cables is listed in
Connector
Length
DC Ooutput
< 30 m
AC Input
< 30 m
Interlock & Status (ILK & STATUS)
< 3 m
Crowbar Enable (CROW. EN)
< 3 m
Persistent Current Switch (PCS)
< 3 m
Remote Sensing (REM. SENS.)
< 3 m
*Trigger Input (TRG. IN)
< 3 m
*Analog Input (AN. IN)
< 3 m
*Auxiliary Input (AUX. IN)
< 3 m
*Thermocouple (K-TYPE TC)
< 3 m
Table 5:
Recommended length for the cables.
*
These connectors are available only with the
ordering option
FB1K5OPT0001
.
WARNING