Using the Training Model

3. As users withdraw fluid from the p

ericardi

al space, it is refilled continuously from the IV bag.

Training

This section provides information about using your model for training and practice.

Ultrasound Scanning

Note: CAE Blue Phantom products do not teach ultrasound procedures or techniques. Refer to your 
institution or training program for more information.

To scan with your training model and conduct a simulated ultrasound-guided procedure:

1. Place the model in the appropriate position for scanning.

2. Place ultrasound gel on the transducer or on the training model in an adequate quantity so that

the transducer slides effortlessly on the model. Add more gel as needed.

3. Adjust the ultrasound system controls per your training protocol and the manufacturer’s

instructions. Optimize the image with the ultrasound controls as needed.

Transesophageal Echocardiogram (TEE/TOE)

To do a TEE/TOE simulation, you will need a transesophageal transducer probe. To use a TEE/TOE probe 
in simulation on a training model, you must lubricate both the transducer and the mouth and throat of the 
training model with ultrasound gel. This additional step is necessary because unlike live patients, the training 
model does not have a naturally-lubricated mouth, throat, and esophagus. Ensure the length of the 
transducer is well-lubricated prior to inserting into the esophagus of the training model.

Transducer covers are often used in exams with real patients. Transducer covers are not necessary when 
using a training model, but you may use them for realism if desired. If you use a transducer cover, follow 
these steps:

1. First, cover the tip of the transesophageal transducer with gel.

2. Next, place the transducer cover over the transducer.

3. Then apply gel to the sheathed transducer in adequate quantities so that the probe slides easily

into the model. Add more gel as needed.

Buildup of dried ultrasound gel should not impair echocardiographic imaging and can easily be cleaned 
from the model. For instructions, see the 

Care and Maintenance

 section of this user guide.

CAUTION

Adjust the fluid level (effusion size) only in the pericardial space. Do not adjust heart chamber 
sizes as this will damage the unit.

Содержание Blue Phantom FAST Exam Ultrasound Training...

Страница 1: ......

Страница 2: ......

Страница 3: ...epair 2 Introduction 3 Anatomy 4 The FAST Models 4 The Echocardiography Pericardiocentesis Models 4 Equipment Overview 5 Using the Training Model 7 Setup 7 Fluid Setup 7 Training 9 Ultrasound Scanning...

Страница 4: ...Contents ii 2022 CAE 905K004752 v1 0 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...ining model Do not pull on the training model skin This can cause the skin to tear Do not mark directly on the training model as this will permanently damage it Do not insert any objects or tools into...

Страница 6: ...cidental fluid exposure Refer to the Material Safety Data Sheet MSDS for guidance May irritate eyes or skin flush well with water May contain pigments that stain clothing wash immediately with cold so...

Страница 7: ...ic and transesophageal BPTEE1702 The FAST models are intended as platforms for the practice of Focused Assessment for Trauma with Sonography FAST and pericardiocentesis procedures Two models are avail...

Страница 8: ...connector Models are delivered with minimal fluid Users must infuse additional fluid to prepare the model for use More information can be found in the Using the Training Model section of this guide Th...

Страница 9: ...g additional items are required for training but not included with shipment Ultrasound system with with cardiac transducer and or TEE TOE probe Ultrasound gel Pericardiocentesis equipment per local pr...

Страница 10: ...Introduction 6 2022 CAE 905K004752 v1 0 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 11: ...odel 3 Set up the training model Put the model in the supine position on a very stable patient bed stretcher or table rated to handle an excess of 200 lbs 91 Kg Do not place the training model on an u...

Страница 12: ...ore before filling for optimal imaging 6 Inject 10 ml of fluid 7 Remove 5 ml of fluid along with any air 8 Repeat steps 4 through 7 until all the air is removed 9 Continue filling according to the tab...

Страница 13: ...OE probe in simulation on a training model you must lubricate both the transducer and the mouth and throat of the training model with ultrasound gel This additional step is necessary because unlike li...

Страница 14: ...it through the esophagus If there is resistance end the procedure immediately Do not flex the transducer excessively while the probe is in the model s esophagus This can damage the esophagus During i...

Страница 15: ...racardiac fluid has two colors Blue in the right heart and red in the left heart As you practice pericardiocentesis you should see clear fluid when you are in the pericardium If you see blue or dark r...

Страница 16: ...Using the Training Model 12 2022 CAE 905K004752 v1 0 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 17: ...pe Store the model with some fluid in any vessels and fluid spaces If these become dry it will damage the model and and cause poor ultrasound imaging If fluid was infused into the model during trainin...

Страница 18: ...ixture into a syringe with tubing attached 5 Put the tubing into the model s throat and infuse the soap mixture through the tube into the esophagus 6 Flush the esophagus and throat with the soap mixtu...

Страница 19: ...help circulate the fluid 3 With a helper tilt the model up 6 10 15 25 cm with the legs higher than the head Make sure to support the head neck 4 Let the model sit for at least one hour to allow any ai...

Страница 20: ...Care and Maintenance 16 2022 CAE 905K004752 v1 0 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 21: ......

Отзывы: