background image

Baseboard/Thermostat Wiring

Thermostat in left junction box:  (Figure A)

1. Locate and cut closed end splice of wires containing limit lead wire

and return wire (wire behind deflector).  Strip 1/2” of insulation from

these two cut lead wires.

a. Join the lead wire from the limit with the lead wire from thermostat

terminal J5L2 with a connector.

b. Join the return wire (wire behind deflector) with the lead wire from

thermostat terminal J1T1 with a connector.

2. Connect the grounding lead of the power supply to the supplied

grounding screw.

3. Connect each of the remaining two power supply leads to each 

lead from the thermostat rocker switch with a wire connector.

a. Be sure the panel does not interfere with the mounting of the 

thermostat plate. Move panel if needed. (Using a rubber-coated

tool, or hammer handle; carefully pry upwards.)

4. Carefully push wiring back into junction box. 

Keep all wires away

from the Smart-Base circuit board. These wires may interfere with

the clock and thermostat’s performance.

Hook upper edge of 

faceplate under lip of case.  Lower bottom edge of faceplate to 

junction box surface and secure thermostat with mounting screw.

5. Rocker switch should be placed in the “O” (OFF) position. To finish

see the “Completion of Installation” section below.

Thermostat in right junction box: (Figure B)

1. Cut closed end splice from connection of element lead wire and

return wire (wire behind deflector).  Strip 1/2” of insulation from

these two cut lead wires.

a. Join the lead wire from the element with the lead wire from 

thermostat terminal J5L2 with a connector.

b. Join the return wire (wire behind deflector) with the lead wire 

from thermostat terminal J1T1 with a connector.

2. Connect the grounding lead of the power supply to the supplied

grounding screw.

3. Connect each of the remaining two power supply leads to each lead

from the thermostat rocker switch with a wire connector.

a. Be sure the panel does not interfere with the mounting of the 

thermostat plate. Move panel if needed. (Using a rubber-coated

tool, or hammer handle; carefully pry upwards.)

4. Carefully push wiring back into junction box. 

Keep all wires away

from the Smart-Base circuit board. These wires may interfere 

with the clock and thermostat’s performance.

Hook upper edge 

of faceplate under lip of case. Lower bottom edge of faceplate to 

junction box surface and secure thermostat with mounting screw.

5. Rocker switch should be placed in the “O” (OFF) position. To finish

see the “Completion of Installation” section below.

FIGURE “A” (Left Junction Box Wiring)

FIGURE “B” (Right Junction Box Wiring)

Completion of Installation

At this point, the baseboard should be securely mounted, and the SBFT2

thermostat wired and secured to the baseboard junction box. The other

junction box should have the baseboard end plate/cover secured in place.
Verify that the thermostat rocker switch is in the “O” (OFF) position 

before reestablishing the electrical power at the panel for power flow 

to the baseboard heater.
Refer to the General Programming Operation Guide for the operation of the

SBFT2 thermostat.

Warranty

WARRANTY:

Warranties  are  non-transferable  and  apply  to  original  consumer

only. Warranty terms are set out below.

LIMITED ONE-YEAR WARRANTY:

Cadet will repair or replace any Cadet product,

including  thermostats,  found  to  be  defective  within  one  year  after  the  date 

of purchase.  

THESE WARRANTIES DO NOT APPLY:

1. Damage  occurs  to  the  product  through  improper  installation  or  incorrect 

supply voltage;

2. Damage  occurs  to  the  product  through  improper  maintenance,  misuse,

abuse, accident, or alteration;

3. The product is serviced by anyone other than Cadet;

4. If the date of manufacture of the product cannot be determined;

5. If the product is damaged during shipping through no fault of Cadet.  

6. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET OUT

HEREIN. CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY

DAMAGE  OR  FOR  CONSEQUENTIAL  DAMAGES  AND/OR  INCIDENTAL

EXPENSES  RESULTING  FROM  BREACH  OF  THESE  WRITTEN  WARRANTIES

OR ANY EXPRESS OR IMPLIED WARRANTY.   

7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PRODUCT,

THE  REPLACEMENT  PARTS  ARE  SUBJECT  TO  THE  SAME  WARRANTIES  AS

THE  PRODUCT.  THE  INSTALLATION  OF  REPLACEMENT  PARTS  DOES  NOT

MODIFY OR EXTEND THE UNDERLYING WARRANTIES. REPLACEMENT OR REPAIR

OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES. 

8. These warranties give you specific legal rights, and you may also have other

rights which vary from state to state. Cadet neither assumes, nor authorizes

anyone to assume for it, any other obligation or liability in connection with its

products other than as set out herein.

If  you  believe  your  Cadet  product  is  defective,  please  contact  Cadet

Manufacturing Co. at 360-693-2505, during the warranty period, for instructions

on how to have the repair or replacement processed. Warranty claims made

after  the  warranty  period  has  expired  will  be  denied.  Products  returned 

without authorization will be refused. 

Parts and Service  

Visit http://support.cadetco.com for information on where to obtain parts and

service.  

Reduce-Reuse-Recycle

This  product  is  made  primarily  of  recyclable  materials.  You  can

reduce your carbon footprint by recycling this product at the end of

its useful life. Contact your local recycling support center for further

recycling instructions.  

©2009 Cadet Manufacturing Co.

Printed in U.S.A.   10/11 #720004

OPer ATInG InSTr ucTIOnS

See the “General Programming Operation” guide for complete operating instructions. The heater and thermostat must be properly installed before

they are used.

Отзывы: