Installation Instructions

PLACEMENT:

For best results install the NLW heater on an inside wall. Headers and bracing are not

necessary. NOTE: The wall can must be installed in the TOP UP position only.

THERMOSTAT: A built-in double pole thermostat is included.

How do I install for new construction?

STEP 1

Mount The Wall Can

The NLW series REQUIRES a minimum distance
of 6 inches from adjacent surfaces and 6 inches
from the floor (See Figure 4). However, Cadet
RECOMMENDS 12 inches from all adjacent
surfaces and 12 inches from the floor for longer
and cleaner performance. Heaters must be
spaced at least 3 feet apart. Secure the wall can
to the studs with four screws (not provided) as
shown in Figure 1.

How do I install in an existing wall?

Cut a hole 14

1

/

8

inches wide by 18

7

/

8

inches high

next to wall stud. The NLW series REQUIRES
a minimum distance of 6 inches from adjacent
surfaces and 6 inches from the floor (See Figure 4).
However, Cadet RECOMMENDS 12 inches from all
adjacent surfaces and 12 inches from the floor for
longer and cleaner performance. Heaters must be
spaced at least 3 feet apart.

FIGURE 2

Front edge of wall can
must extend

1

/

2

or

5

/

8

inch from face of stud
to allow for thickness
of sheetrock.

6

6

19

1

/

4

1

/

4

READ ALL

INSTRUCTIONS

AND SAFETY

INFORMATION

Part One

IMPORTANT!

It is extremely

important you
verify that the

electrical supply

wires are the same

voltage as the

heater (i.e. 120 volt

heater to 120 volt

power supply and

240 volt heater

to 240 volt power

supply). If

replacing an

existing heater,

check the labels of

the old heater and

replace using the

same voltage.

Hooking a 240 volt

heater to a 120 volt

power supply will

drastically reduce

the heater's

output. Hooking a

120 volt heater to a

240 volt power sup-

ply will destroy the

heater. Connecting

your heater to an

incompatible

power supply will

void the warranty.

STEP 1

Cut Hole In Wall

FIGURE 4

FIGURE 1

KNOCK-OUT

      KNOCK-OUT

(TWIST T

   (TWIST TOO

REMOVE)

REMOVE)

KNOCK-OUT

  (TWIST TO

REMOVE)

STRAIN RELIEF

CONNECTOR

SUPPLY

WIRE

FIGURE 3

GROUNDING

GROUNDING

WIRE

WIRE

GROUNDING

WIRE

GROUNDING

GROUNDING

SCREW

SCREW

GROUNDING

SCREW

TOP

VIEW

ALAMBRE

STEP 2

Route Supply Wires

Route supply wire from circuit breaker to top of wall
can. Remove knockout and attach the supply wire
with a strain relief connector, leaving 6 inches of
wire lead for later use. Connect supply ground wire
to grounding screw in wall can (See Figure 3).
Proceed to PART TWO.

STEP 2

Route Supply Wires

Route supply wire from circuit breaker to top
of wall can. Remove knockout and attach the
supply wire with a strain relief connector, leaving
6 inches of wire lead for later use. Connect
supply ground wire to grounding screw in wall
can (See Figure 3). Proceed to PART TWO.

STEP 3

Mount The Wall Can

Insert wall can into opening. Keeping front of
wall can flush with wall, secure to wall stud with
four screws.

STEP 4

Connect Ground Wire

Connect supply ground wire to grounding screw
in wall can (See Figure 3). Proceed to PART TWO.

Содержание NLW302TW

Страница 1: ...local codes 4 Connect the grounding pigtail copper wire provided in the wall can to the supply ground wire 5 If you need to install a new circuit or need additional wiring information consult a qualif...

Страница 2: ...s the heater i e 120 volt heater to 120 volt power supply and 240 volt heater to 240 volt power supply If replacing an existing heater check the labels of the old heater and replace using the same vol...

Страница 3: ...ermostat knob just above the OFF position Maintenance As needed or every six months minimum 1 WARNING Before removing grill turn the electrical power off at the electrical panel board circuit breaker...

Страница 4: ...r fan operates but does not discharge warm air Heater will not shut off Heater discharges smoke or emits a burnt odor Element heats for a moment without the fan turning then immediately stops heating...

Страница 5: ...n la c mara de pared al alambre de puesta a tierra del suministro 5 Si se debe instalar un nuevo circuito o se necesita informaci n adicional sobre el cableado consulte a un electricista calificado 6...

Страница 6: ...re del suministro desde el corta circuito a la parte superior de la c mara de pared Retire una de las piezas desmontables y empalme el alambre de suministro mediante un conector de alivio de tensi n d...

Страница 7: ...gire la perilla en el sentido de las manecillas del reloj Ventilador funcionando continuamente sin calor 1 Gire el interruptor del ventilador a la posici n de ventilador 2 Gire la perilla del termosta...

Страница 8: ...or no funciona Tabla de Resoluci n de Problemas 1 Voltaje de suministro incorrecto 2 Circuito sobrecargado 3 Hay un cortocircuito en los cables de suministro o del calentador 4 Cortacircuito defectuos...

Отзывы: