INSTALLATION INSTRUCTIONS
3
GROUNDING PLUG AND RECEPTACLE REQUIREMENTS
1.
WARNING: Risk of fire. Do not
use as a residential or household
heater.
2. Do not use outdoors.
3. This heater is not intended for use
in bathrooms, laundry areas, and
similar indoor locations.
4. CAUTION: Do not operate without
stand attached.
5. Heater must be kept clear of
all obstructions: 3 foot (92 cm)
minimum clearance from front, 6
inch (16 cm) minimum clearance
from back and top, and 12 inch
(30.5 cm) minimum clearance
from sides. See Figure 2.
6. Always plug the heater directly
into a 240 volt wall receptacle.
Never use an extension cord.
PARTS OF YOUR HEATER
This heater is for use with 240 volts. The cord has a 20 amp or 30 amp plug
as shown in Figure 1. No adapter is available for these blade configurations,
and none should be used. The Hot One requires a 240 volt grounded
receptacle. When properly installed, it provides a ground connection through
the cord to the heater to protect the operator from electric shock. Do not use
an extension cord, power strip or any kind of adapter.
Unanswered questions? Call our technical support team in Vancouver,
Washington at
855.CADET.US
or outside the US at 360.693.2505.
Plug Configuration
Receptacle Configuration
RCP402S - 20 Amp
RCP502S - 30 Amp
Receptacle Configuration
Plug Configuration
NEMA #6-30R
NEMA #6-20R
Figure 1
8-1/4"
20.9 cm
8-1/4"
20.9 cm
17-1/2"
44.5 cm
15-3/4"
40 cm
Manual Reset
Limit Button
Thermostat
Knob
Power
Indicator
Light
ON/AUTO
Controls
Watts HI/
LOW