36
WALL - SMALL - STYLE
EN
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Stove running and
display showing
"HOT EXHAUST"
Reached fume
outlet limit
temperature
The stove runs at minimum. NO PROBLEM!
Stove running and
display showing
"SERVICE"
Routine
maintenance
alert (it does not
block the system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before
maintenance. Contact the service centre.
16
TECHNICAL DATAS
16.1
REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove
mechanical components.
•
For fuse replacement in the electric socket which lies on the under of the stove, extract the fuses to change
with the aid of a screwdriver in the shutter (see
).
Fig. 50 - Shutter with the fuse to remove
Proceed as follows:
•
Remove the letf panel and you can have access at the following components: pressostat siliconic pipe, fume
fan and ambient fan.
•
Remove the right panel and you can have access at the following components: ambient probe, geared
motor, and manual reset switch.
•
Remove the inspection panel and you can have access at the following components: pressostat, thermostat,
electronic board and ingnition plug.
•
For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and
to extract it, unscrew the two screws lying under the geared motor of the auger, remove the hand rejector
inside the hopper and then unscrew the inner bolt of the auger. To assembly proceed at the contrary.