32
WALL - SMALL - STYLE
EN
ALARM
CAUSE
SOLUTION
INTERVENTION
AL 3 - HOT
EXHAUST
Faulty fume probe
Replace the fume probe.
Faulty mother board
Replace the electronic board.
The exchanger fan does
not work
Replace the ambient fan.
Too high pellet drop
value
Adjust the pellet loading.
AL 4 - FAN
FAILURE
Faulty protection fuse of
the fume fan
Replace the fuse (1,25A).
Faulty fume fan
The pellets can burn also thanks to the chimney flue
depression and without the aid of the fume fan. Have
the fume fan replaced immediately. It can be noxious to
health to let the stove running without fume fan.
AL 5 - FAILED
IGNITION
Empty hopper
Fill the hopper.
The burning pot has not
been cleaned
Clean the burning pot.
The ignition threshold has
not been reached
Clean the burning pot and switch the stove on again.
Faulty ignition plug
Replace the ignitor resistance.
Too sever external
temperature
Start the stove up again.
Humid pellet
The pellets must be stored in a dry place. Please check it.
Blocked thermal probe
Replace the thermal probe.
Faulty mother board
Replace the mother board.
AL 6 - NO
PELLET
Empty hopper
Full the hopper.