SATURNO 16 - 24
18
Keep away from the stove and, as previously mentioned, air out the room. The smoke and the smell of paint will dissipate after
about an hour of operation; in any case, remember that they are not harmful to health.
The stove is subjected to expansion and contraction during the ignition and cooling phases; as such, it may make slight creaking
sounds. This is absolutely normal, as the structure is built in laminated steel, and is not to be considered a defect.
It is extremely important to make sure not to overheat the stove right away, but rather heat it gradually to the desired temperatu-
re, initially using low power. This will prevent damage to the ceramic plates or coil, welding, and steel structure.
DO NOT IMMEDIATELY EXPECT HEATING EFFICIENCY!!!
ATTENTION!
If smoke flows into the room from the appliance or the flue during operation or initial ignition, switch off the
device, air out the room, and immediately contact the installation/customer service technician.
10.3 POWER OUTPUT
Once the start-up stage is complete the control panel will display ON with a fixed flame at level 3. The subsequent flame modula-
tion at lower or higher powers is managed autonomously and upon reaching the temperatures set in the “System configuration”.
Fig. 9 - big Flame
Fig. 10 - small Flame
10.4 ADJUSTMENTS MENU
To access the adjustments menu act as follows:
• Press the + - keys
• Scroll with the <> arrows and select “Set Room T” or “Set Water T” or “Exchanger Speed”
• Press “menu” to access the selected option.
• Modify with the + - keys.
• Press “menu” to confirm and “esc” to exit.
Fig. 11 - Display
Note: The full stop to the right of the ambient temperature shown in the control panel display (upper right) indicates the half
degree (e.g. 23.° means 23.5°C).
Air V. Speed
- this function allows selecting the desired speed for the ambient fans from 1 to 5 or A. A means automatic, ventila-
tion depends on power, recommended setting (see
10.5 NORMAL SHUTDOWN (ON THE PANEL: OFF WITH FLASHING FLAME)
If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the
automatic execution of the following stages:
• It stops pellets loading
• The room fan (if provided) maintains the set speed until the smoke T reaches 100°C, then it automatically sets itself at the
minimum speed until it reaches the shutdown temperature
• The smoke fan sets itself at maximum speed and maintains it for a fixed time of 10 minutes, at the end of which if the smoke