RIVER IDROTECH 18 - 24 - 24H2O
45
11 FEATURES
DESCRIPTION
RIVER IDROTECH
18 T1
RIVER IDROTECH
24 T1
RIVER IDROTECH
24H2O T1
WIDTH
53,6 cm
53,6 cm
53,6 cm
DEPTH
55,9 cm
55,9 cm
55,9 cm
HEIGHT
111,5 cm
111,5 cm
111,5 cm
WEIGHT
136 kg
136 kg
136 kg
Effective rated power (H
2
O)
12,7 kW
18,2 kW
18,2 kW
Minimum effective power (H
2
O)
2,3 KW
2,3 KW
2,3 KW
Maximum operating pressure
2 bar – 200 kPa
2 bar – 200 kPa
2 bar – 200 kPa
INTRODUCED THERMIC POWER (Min/Max)
4,6 - 18,7 kW
4,6 - 26 kW
4,6 - 26 kW
NOMINAL THERMIC POWER (Min/Max)
4,4 - 17,7 kW
2,6 - 8,5 kW
2,6 - 8,5 kW
EFICIENCY (Min/Max)
95,9 - 94,8 %
95,9 - 92,9 %
95,9 - 92,9 %
FUME TEMPERATURE (Min/Max)
55 - 107 °C
55 - 142 °C
55 - 142 °C
FUME MAXIMUM LOADING CAPACITY (Min/Max)
5,4 - 10,6 g/s
5,4 - 14,2 g/s
5,4 - 14,2 g/s
CO EMISSIONS (13% O
2
) (Min/Max)
0,017 - 0,009 %
0,017 - 0,014 %
0,017 - 0,014 %
OGC EMISSIONS (13% O
2
) (Min/Max)
6 - 2 mg/Nm
3
6 - 1 mg/Nm
3
6 - 1 mg/Nm
3
NO
X
EMISSIONS (13% O
2
) (Min/Max)
100 - 99 mg/Nm
3
100 - 92 mg/Nm
3
100 - 92 mg/Nm
3
Medium CO CONTENTS at 13% O
2
(Min/Max)
209 - 106 mg/Nm
3
209 - 169 mg/Nm
3
209 - 169 mg/Nm
3
Medium POWDER CONTENTS at 13% O
2
(Min/Max)
12 - 10 mg/Nm
3
12 - 12 mg/Nm
3
12 - 12 mg/Nm
3
CHIMNEY DEPRESSION (Max)
12 Pa - 2 Pa***
12 Pa - 2 Pa***
12 Pa - 2 Pa***
ON SHARED CHIMNEY FLUE
NO
NO
NO
FUME OUTLET DIAMETER
Ø80 mm
Ø80 mm
Ø80 mm
COMBUSTIBLE
Pellet Ø6-7 mm
Pellet Ø6-7 mm
Pellet Ø6-7 mm
PELLETS HEATING VALUE
5 kWh/kg
5 kWh/kg
5 kWh/kg
PELLETS HUMIDITY
≤ 10%
≤ 10%
≤ 10%
HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/Max)
123 - 496 m
3
**
123 - 678 m
3
**
123 - 678 m
3
**
HOURLY CONSUMPTION (Min/Max)
1 - 3,9 kg/h*
1 - 5,4 kg/h*
1 - 5,4 kg/h*
HOPPER CAPACITY
24 kg
24 kg
24 kg
RANGE (Min/Max)
24 - 6 h
24 - 4 h
24 - 4 h
SUPPLY
230 V - 50 Hz
230 V - 50 Hz
230 V - 50 Hz
POWER INPUT (Max)
370 W
370 W
370 W
INGNITER RESISTANCE POWER INPUT
300 W
300 W
300 W
MINIMUM EXTERNAL AIR INLET (last effective area)
80 cm
2
80 cm
2
80 cm
2
STOVE WITH SEALED CHAMBER
YES
YES
YES
EXTERNAL AIR INLET FOR SEALED CHAMBER
60 mm
60 mm
60 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/bottom)
200 / 300 / 0 mm
200 / 300 / 0 mm
200 / 300 / 0 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front)
- / 1000 mm
- / 1000 mm
- / 1000 mm
* Values that can vary depending on the type of pellet used
** Heatable volume depending on the power required per m
3
(respectively, 40-35-30 Kcal/h per m
3
)
*** Value recommended by the manufacturer (not binding) for optimal product performance
Tested according to EN 14785 in compliance with the European Construction Product regulation (EU 305/2011)