• Connect with a flexible or stiff hose with a 60 mm diameter and a maximum length of 2 metres (see
Fig. 12
).
Fig. 11 - Cut- Removal
Fig. 12 - Connections
How to connect to the stove in the sealed chamber with concentric system:
• Insert the N fitting into the I air intake pipe (see
Fig. 13
and
Fig. 14
). Connect N to Q using a flexible tube which can resist a
temperature of 100°C (a flexible aluminium tube is recommended).
• Maximum height for the installation of a vertical exhaust flue (roof) HV = 6 mt (see
Fig. 15
).
• Maximum height for the installation of a horizontal exhaust flue (wall) HO = 2.6 mt (see
Fig. 15
).
Fig. 13 - Flexible tube
Fig. 14 - Connections
Fig. 15 - Flue connections
LEGEND
Fig. 13 - Fig. 14 - Fig. 15
I
Combustion air intake with a diameter of 40 mm
N
Rubber fitting with a diameter of 40/60 mm
R
Flexible aluminium tube
Q
Coaxial pipe air combustion connection
Y
Coaxial pipe air combustion intake
HO
Height of coaxial flue with wall/horizontal exhaust
HV
Height of coaxial flue with roof/vertical exhaust
5
INSTALLATION
5.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation,