background image

Stufe a pellet

25

12.6  GEAR MOTOR

If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of 

cooling is reached.

12.7  TEMPORARY POWER CUT

If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a cooling/restart 

cycle.

12.8  FAILED START-UP

If during ignition no flame develops, the boiler will go into alarm condition.

12.9  BLACKOUT WITH THE BOILER ON

In the event of a power cut (BLACKOUT) the boiler behaves as follows:

•  Blackout below 10”: it returns to its operation in progress;

•  In the event of a power cut that lasts over 10” with the boiler on or in the start-up stage, when the boiler is powered again it 

goes back to the previous operating condition with the following procedure:

1)  It performs a cooling phase to the maximum.
2)  Performs a new ignition.

During stage 1 the panel displays ON BLACK OUT.

During stage 2 the panel displays Start-up.

If during stage 1 the boiler receives commands from the panel and thus carried out manually by the user, then the boiler stops 

executing the blackout recovery status and proceeds to restart or shutdown as requested by the command.

12.10  ALARM ALERTS

Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condition.

The control panel gives information on the reason of the alarm in progress.

PANEL ALERT

TYPE OF PROBLEM

SOLUTION

A01

The fire does not ignite.

Check whether the brazier is clean / level of pellets in the 

hopper.

Check pellet level in the tank. 

Check  that  the  burning pot  is  correctly  positioned in its 

case and does not contain deposits or unburned material. 

Check that the pellet cover and the fire door are correctly 

closed.

Clogged flue

Damaged ignition resistance 

A02

The fire goes off abnormally.

Check the level of pellets in the hopper.

A03 Thermostat 

alarms

The temperature of the pellets hopper or the 

water temperature exceed the envisioned safety 

threshold.

Wait for the cooling stage to end, cancel the alarm and 

restart the boiler setting the fuel loading at minimum 

(SETTINGS menu - Pellet Recipe).

Check that dust does not clog the aeration grid on the stove 

back.

If the alarm persists, contact the service centre. Check if the 

room fan works properly (if present).

A04

Smoke overheating.

The set smoke threshold has been exceeded. Reduce pellets 

loading (SETTINGS menu - Pellet Recipe).

A05 Pressure 

switches alarm

Flue gas pressure switch trip.  (see SMOKE RPM 

VARIATION User Manual)

Check for chimney obstructions/fire door opening, pellet 

tank opening, gasket seals, side fire ducts cleaning, clogged 

hose connection, excess flue length, unfavourable weather 

conditions and clogged stove.

A08

Abnormal smoke fan operation.

If the alarm persists, contact the service centre.

A09

Smoke probe faulty.

If the alarm persists, contact the service centre.

SERVICE

Routine maintenance alert (it does not block the 

system).

When this flashing message appears upon start-up, it 

means that the preset operating hours have elapsed before 

maintenance. Contact the service centre.

Содержание Cristal 7 Up

Страница 1: ...T3 7 7 0 PERLA3 7 7 0 CRISTAL3 7 7 0 7 0 UP ONE AIRTIGHT BEAM AIRTIGHT ACCENT AIRTIGHT SHARP AIRTIGHT LEE AIRTIGHT CHROME 5 7 AIRTIGHT ROUND 5 7 AIRTIGHT SOUND3 5UP 7UP EN 2022CADELsrl Allrightsreserv...

Страница 2: ...FEATURE SEESECTIONXSETTINGSMENU A PAG 13 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 21 8 19 CHIMNEY SWEEP FUNCTION FOR...

Страница 3: ...an request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninst...

Страница 4: ...val between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of the produ...

Страница 5: ...the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The el...

Страница 6: ...tisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty the inspect...

Страница 7: ...customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheappliancethataris...

Страница 8: ...DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance wit...

Страница 9: ...Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must not...

Страница 10: ...ECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE FOAM PEANUTS POLYSTYRENE PS 6 SORTED waste collection PLASTIC Check...

Страница 11: ...g com it documenti 7 2 NAVEL STAND ALONE OPTIONAL Procedureifonlyvalidformodelswith NAVELSTANDALONEWi Fitechnology ATTENTION InstallationmustONLYbecarriedoutbyspecialisedpersonnel The manufacturer wil...

Страница 12: ...After 2 hours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrence can be attri butedtodifferentre...

Страница 13: ...items that are accessed are Time and Date Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Sele...

Страница 14: ...ing the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit c Screw Loading To select Screw loading only when the boiler is switched off act as follows Press the...

Страница 15: ...Scroll to Pellet Recipe using the arrows Press menu to confirm Modify the with the keys Press menu to confirm and esc to exit i Smoke Fan rpm To change the parameter act as follows Press the menu but...

Страница 16: ...operating mode and shows the selected heat output the ambient temperature and the big flame see Fig 11 If the ambient temperature value exceeds the limit set on the button panel in the temperature set...

Страница 17: ...ress menu to access the selected option Modify with the keys Press menu to confirm and esc to exit Set Room T this function allows setting the desired temperature in the room where the stove is instal...

Страница 18: ...tionofthetimer There are sixTIMER programmes for each one the user can decide the start up and shutdown time as well as the day of the week in which it is active Whenoneormoreprogrammesareactive thepa...

Страница 19: ...at the time set on the active timer 8 14 AUTO ECO MODE SEE SECTION F G SETTINGS MENU A PAG 13 To activate the Auto Eco mode and adjust the time refer SETTINGS MENU a pag 13 Thepossibilitytoadjustthe t...

Страница 20: ...ainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature makes it possible to adjust combust...

Страница 21: ...se with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtech...

Страница 22: ...r pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecertificationsinclude forexample ENPlus DINplus NormM7135 andspecifical...

Страница 23: ...ding system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 27 10 VENTI...

Страница 24: ...aust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the temperat...

Страница 25: ...M SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned in its case...

Страница 26: ...rationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had bee...

Страница 27: ...dinametalcontainerwithasealedlidandthiscontainermustnevergetintouchwithcombu stible materials for example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the e...

Страница 28: ...ing them in evidence 13 9 GASKET REPLACEMENT Incaseofdeteriorationoffiredoor hopperorfumechambergaskets itisnecessary toreplacethembyanautorizedtechnicianin order to guarantee the good running of the...

Страница 29: ...becarriedout withascheduledservicecontract Thisoperationconsistsofavisual andfunctionalinspectionoftheinternalcomponents Asummaryofthechecksand ormaintenanceoperationsthatareessential for the correct...

Страница 30: ...n fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Страница 31: ...Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Страница 32: ...l 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat outp...

Страница 33: ...mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at m...

Страница 34: ...mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at m...

Страница 35: ...mg Nm3 Heat output Nominal heat output Pnom 5 5 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at...

Страница 36: ...minal heat output Pnom 5 5 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimum heat output i...

Страница 37: ...minal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimum heat output ind...

Страница 38: ...NOTE...

Страница 39: ...NOTE...

Страница 40: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 01 2022...

Отзывы: