MIMINUM CLEARANCES
A
24" (610 mm)
G
8" (203 mm)
B
18" (457 mm)
H
1.5" (mm)
C
6" (152 mm)
I
24" (610mm)
D
1" (25 mm)
J
24" (610mm)
E
72" (1829 mm)
K
9" (229mm)
F
24" (610 mm)
-1-
HEAT SHIELD
22.4. FLOOR PROTECTION
See Section 9.7.4 - FLOOR PROTECTION
22.5. HOT AIR PLENUM
See Section 9.12 - HOT AIR PLENUM
22.6. CONNECTING PIPE AND MANUAL DAMPER
The pipe connecting the furnace to the chimney must be as short and as straight as possible. If a deviation is required,
the use of 45
o
elbows is highly recommended for a better evacuation of the smoke in the chimney of the wood burning
furnace. The barometric damper provided with the appliance must be installed on the oil unit evacuation pipe,
approximately 24" from the flue outlet of the unit.
TYPE OF FURNACE
OIL BURNING UNIT FLUE
PIPE DIAMETER
MAX CADDY
5"