DOC02- CDC MC MADI Issue A - November 2016
Front Panel Dip Switch 3 Setting for Different Sample Rates
Fsample
DIP 1 / FS 0
96 kHz
ON
48 kHz
OFF
Front Panel Dip Switch 4 and 5 Settings for Different WORD CLOCK Modes
Mode
DIP 4
DIP 5
CDC MC MADI is SLAVE to WORD CLOCK derived from the
MADI link from third party equipment
ON
Word Clock
Led = S
OFF
SYNC LED
= MADI
CDC MC MADI is SLAVE to a WORD CLOCK provided at WORD
CLOCK BNC input port
ON
Word Clock
Led = S
ON
SYNC LED
= Word Clock
CDC MC MADI is the MASTER WORD CLOCK and provides
WORD clock to the MADI link
OFF
Word Clock
Led = M
X – Don’t care
SYNC LED =
Both OFF
Important Notes
•
DIP switches 6, 7 and 8 are
NOT USED
.
•
WORD CLOCK Modes adopted by the MADI unit connected should be appropriate to the
CDC MC MADI WORD CLOCK source settings selected.
•
Sample rate settings on the MADI equipment connected, should
mimic
the CDC MC MADI
settings selected.
•
Ext WORD CLOCK input BNC/Coaxial signal frequency (if used) must mirror the FS settings
of the system.
•
Definitions of Master / Slave operation above DO NOT relate to MegaCOMMS. The CDC MC
MADI will always operate as MegaCOMMS SLAVE when connected to either a CDC MC
Router or a CDC series console.