Be sure to keep fireplace dampers closed when not in use . They provide 
an excellent escape route for heat, as well as humidity . 
On occasion, indoor moisture producing activities such as clothes drying, 
cooking, showers, etc ., may raise the humidity level higher than it should 
be, even though the humidifier is not operating . Telltale indications are 
condensation or frost on cold surfaces such as windows, doors, walls, 
etc . If such condensation persists for several hours, your home should be 
ventilated to dissipate the potentially damaging excess moisture .

ADDITIONAL INFORMATION

MAINTENANCE

NOTE:

 The manufacturer of the device recommends that service be 

performed only by a qualified technician . Contact your installing contractor 
for service . See Cautions and Warnings on pages 2 and 3 prior to 
attempting these procedures .

Turn humidifier off and allow humidifier to drain. Disconnect 
power before servicing.

Inspect Humidifier at approximately 500 hour intervals or several times 
during the humidification season .
•  Check system operation and inspect all plumbing connections and piping 

for signs of cracks or leaks .

•  Inspect drain line to make sure it is not blocked and has constant 

downward slope . Clean or replace if necessary .

•  Inspect steam hose to make sure it has no low spots and has constant 

upward slope from humidifier to dispersion tube in duct . If dispersion 
tube is mounted below humidifier, inspect drip tee drain .

Replace the canister annually and when prompted by the “Service” light .  
Use only genuine replacement part number 8045HUM .
1 .   Press On/Off switch to turn humidifier off . Humidifier will drain for four 

minutes .

2 .   Allow humidifier to drain . When the green “drain” LED stops flashing, 

disconnect main electrical power to humidifier .

3 .   Remove front panel .
4 .   Pull three wires off posts on top of canister . (Two large electrode 

conductors and one water level probe conductor .)

5 .   Loosen hose clamp at top of canister .
6 .   Slide hose off top of canister .
7 .   Slide canister up and out of drain assembly . Discard canister .
8 .   Remove o-ring from drain assembly using small screw driver .
9 .   Inspect drain assembly and remove any debris . See drain valve cleaning 

procedure in Installation & Maintenance manual .

10 .   Insert new o-ring into slot in drain assembly . (O-ring is provided with 

canister .) Dampen o-ring with water before inserting canister . Do not use 
oil, grease, or any lubricant besides water .

11 .   Make sure strainer is inserted into bottom of new canister .
12 .   Insert canister into drain assembly . Position canister with label facing 

outward .

13 .   Slip steam hose over top of canister and tighten hose clamp .
14 .   Reattach three wires to posts on top of canister . (Larger electrode 

conductors are interchangeable .)

15 .   Replace front panel .
16 .   Inspect drain line to make sure it is not blocked and has constant 

downward slope . Clean or replace if necessary .

17 .   Inspect steam hose to make sure it has no low spots and has constant 

upward slope from humidifier to dispersion tube in duct . If dispersion 
tube is mounted below humidifier, inspect drip tee drain .

18 .   Restore electrical power to humidifier .
19 .   Turn humidifier on and verify green On/Off light is illuminated .
20 .   See Start-up procedure in Installation, Operation & Maintenance manual .

TO REpLACE THE CANISTER

TO SERVICE FILL VALVE

If water flow from fill valve is restricted, disconnect inlet fitting and remove 
in-line strainer using small screw from inlet port . Clean or replace strainer . 

Turn the control knob to the maximum RH setting . Make sure that the 
water saddle valve is open and that the humidifier is on . The indoor unit 
blower must be running for the humidifier to function . Once humidifier 
operation is verified, reduce the Humidifier Control setting to the 
recommended inside humidity, depending on the outside temperature . 

If using the automatic humidifier control model number 
kUAWC0101CAC or kUAWC0101BRy, DO NOT LEAVE IN TEST 
MODE AS HUMIDIFIER WILL NOT OpERATE. 

CHECk THE HUMIDIFIER OpERATION

Содержание HUMXXSTM3034

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMXXSTM3034 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier ...

Страница 2: ... until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system Electrical shock hazard If the humidifier starts up responding to a call for humidity during maintenance severe bodily injury or death from electrical shock could occur Follow the procedures in this manual before performing service or ma...

Страница 3: ...m and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your recent steam humidifier purchase We appreciate your business and are pleased to add your name to our growing list of customers You have invested in the highest quality equipment available Your humidi...

Страница 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in this state until the rated output is reached The conductivity of naturally soft water hard water and softened water changes as the water heats up but the internal controller adjusts the water level to...

Страница 5: ...rent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects over current which can be caused by failure to drain or other system failures Call your heating and air conditioning dealer for service HUMIDIFIER CONTROL OPERATING INSTRUCTIONS The control provided...

Страница 6: ...obe conductor 5 Loosen hose clamp at top of canister 6 Slide hose off top of canister 7 Slide canister up and out of drain assembly Discard canister 8 Remove o ring from drain assembly using small screw driver 9 Inspect drain assembly and remove any debris See drain valve cleaning procedure in Installation Maintenance manual 10 Insert new o ring into slot in drain assembly O ring is provided with ...

Страница 7: ...Form OG HUMXXSTM 01 10009952 B2205831A 10 12 2012 CAC BDP 7310 West Morris St Indianapolis IN 46231 ...

Отзывы: