CAC / BDP DHMVHA Скачать руководство пользователя страница 8

8                                                                 

Specifications subject to change without notice.                                                                         OM-DHMVHA-01

FEATURES

The unit provides the following features for added comport and safety.

Time Delay

If 

ON/OFF

 is pressed too soon after a stop, the compressor will not 

start for 3 to 4 minutes due to the inherent protection against frequent 
compressor cycling. The unit only emits an audible beep when the 
signals are received correctly.

Heating

If the unit is in 

HEATING

 mode, there is a delay when the fan starts. 

The fan starts only after the coil is warmed up to prevent cold blow.

Auto Defrost Operation

In 

HEATING

 mode, if the outdoor coil is frosted, the indoor fan and 

outdoor fan turns off while the system removes the frost on the 
outdoor coil. The system automatically reverts to normal operation 
when frost is removed from the outdoor unit.

Auto Start

If the power fails while the unit is operating, the unit stores the 
operating condition, and it will start operation automatically under 
those conditions when the power is restored.

Auto-Restart (some units)

If the unit loses power, it automatically restarts with the prior settings 
once power has been restored.

Anti-mildew (some units)

When turning off the unit from 

COOL

AUTO 

(

COOL

), or 

DRY

 

modes, the air conditioner continues to operate at very low power to 
dry up any condensed water and prevent mildew growth.

Wireless Control (some units)

Wireless control allows users to control the air conditioner using a 
mobile phone and a wireless connection. For the USB device access, 
replacement, maintenance operations must be carried out by 
professional staff.

Louver Angle Memory (some units)

When turning on the unit, the louver automatically resumes its former 
angle.

Active Clean (some units)

The 

Active Clean Technology

 washes away dust, mold, and grease 

that may cause odors when it adheres to the heat exchanger by 
automatically freezing and then rapidly thawing the frost. The 
operation produces more condensed water to improve the cleaning 
effect.

After cleaning, the blower wheel keeps operating with hot air to blow-
dry the evaporator, thus preventing the growth of mold and keeping 
the inside clean. When this function is turned on, the indoor unit 
window displays 

CL

. After 20 to 45 minutes, the unit turns off 

automatically and cancels the function.

Breeze Away (some units)

This feature avoids direct air flow from blowing on inhabitants. 

Refrigerant Leak Detection (some units)

The indoor unit automatically displays 

EL0C 

when it detects 

refrigerant leakage.

Occupancy Sensor (some units)

The system is controlled intelligently under the 

Occupancy Sensor 

mode. The feature detects the movement in the room. In 

COOLING

 

mode, when occupants are away for 30 minutes, the unit automatically 
lowers the frequency to save energy (for Inverter models only). And 
the unit automatically starts and resumes operation when movement is 
detected.

Resetting the Remote Control

If the batteries in the remote control are removed, the current settings 
cancel and the control returns to the initial settings and enters the 

STANDBY mode

. Push 

ON/OFF

 to activate.

NOTE: For multi-zone air conditioners, the following functions 
are not available: ACTIVE CLEAN, SILENCE, BREEZE AWAY, 
REFRIGERANT LEAKAGE DETECTION and ECO.

Setting Vertical Angle of Air Flow

While the unit is on, press 

SWING

 on the remote control to set the 

direction (vertical angle) of airflow.

NOTE: When using the COOL or DRY mode, do not set the 
louver at too vertical an angle for long periods of time. Doing so 
can cause water to condense on the louver blade, which may drop 
on your floor or furnishings.

When using the COOL or HEAT mode, setting the louver at too 
vertical an angle can reduce the performance of the unit due to 
restricted air flow.

Setting Horizontal Angle of Air Flow

The horizontal angle of the airflow must be set 

manually

. Grip the 

deflector rod (see Fig. 11 — on page 9) and manually adjust it to your 
preferred direction. For some units, the horizontal angle of the airflow 
can be set by remote control.

Содержание DHMVHA

Страница 1: ...ease record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your syste...

Страница 2: ...ngle zone applications only Using AUTO CHANGEOVER on multi zone applications could set an indoor unit to STANDBY mode indicated with two dashes on the display STANDBY mode turns off the indoor unit un...

Страница 3: ...s activated some units for 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENCE feature is turned off when defrosting cooling and heating units when anti cold air feature is turned on when uni...

Страница 4: ...nter the energy efficient Sleep Fresh Follow Me AP mode J J J Enables unit to reach preset temperature in the shortest possible time Selects fan speeds in the following order AUTO LOW MED HIGH J J NOT...

Страница 5: ...ay If flashes Displays when LOCK feature is activated Lights up when remote sends signal to indoor unit Displays the current including mode Displays when ECO feature is activated Displays when GEAR fe...

Страница 6: ...NTROL OPERATION QUICK START Remote Control Operation Quick Start NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the right side of the unit The...

Страница 7: ...operation based on the set temperature Fig 7 AUTO Mode 1 Press MODE to select AUTO 2 Set your desired temperature using TEMP or TEMP 3 Press ON OFF to start the unit NOTE FAN Speed can not be set in...

Страница 8: ...he operation produces more condensed water to improve the cleaning effect After cleaning the blower wheel keeps operating with hot air to blow dry the evaporator thus preventing the growth of mold and...

Страница 9: ...button on the right hand side panel of the unit see Figure 12 2 Press MANUAL CONTROL one time to activate FORCED AUTO mode 3 Press MANUAL CONTROL again to activate the FORCED COOLING mode 4 Press MANU...

Страница 10: ...the instructions Failure to do so could cause leakage and result in personal property damage fire and electric shock Ensure all wires are connected properly Failure to connect wires according to inst...

Страница 11: ...5 Rinse the filter with fresh water then shake off any excess water 6 Dry it in a cool dry place and refrain from exposing it to direct sunlight 7 When dry re clip the air freshening filter to the lar...

Страница 12: ...outdoor units Energy Saving Recommendations The following recommendations add greater efficiency to the ductless system Select a comfortable thermostat setting and leave it at the chosen setting Avoid...

Страница 13: ...cause white mist to emit from the indoor unit Both the indoor and outdoor units emit white mist When the unit restarts in HEAT mode after defrosting white mist may be emitted due to moisture generate...

Страница 14: ...ce representative Call your service representative Cooling is Not Working Properly The filter is blocked with dust Temperature is not set properly A window or door is open The outdoor unit is obstruct...

Отзывы: